Hydrogen Sensor Refrigerant Gas Tolerant Sensor - SenseH2-R
• H2 range (in air): 0.25 - 4.0% H2
• Voltage input: 12 - 24 Vdc
• Output (sensing range): 1.0 - 4.5Vdc
• Response time (T90): 5 Sec.
• Recovery time (T10): 5 Sec.
• Ambient temperature: -20~80°C
• Relative humidity: 5~95%R.H.
- Quantity:
- - +
Product Specification
SenseH2-R Hydrogen Sensor (H2 Sensor) Features
• High sensitivity and selectivity to hydrogen
• Fast response and recovery times
• Immune to signal saturation
• Robust to widely varying ambient flow rates
• Compact and rugged design
• 1.0 to 4.5V output, spans 0.25 to 4.0% H2 in air (5 to 100% LFL)
SenseH2-R Hydrogen Sensor (H2 Sensor) Intended Uses:
The NTM SenseH2-R is intended for use as a hydrogen gas detector in the range of 0.25 to 4% hydrogen in air. This sensor is tolerant to halogen gasses commonly found in refrigerant gases and fire suppression systems.
SenseH2-R Hydrogen Sensor (H2 Sensor) Typical applications include:
• Uninterruptible power supply (UPS) systems monitoring,
• Telecom systems monitoring Stationary fuel cells ,
• Laboratory monitoring
• Motive power charging stations
SenseH2-R Hydrogen Sensor (H2 Sensor) Table of Typical Characteristics:
Metric |
Min |
Max |
Units |
Characteristics: |
|
|
|
H2 range (in air) |
0.25 | 4.0 |
% |
Voltage input |
12 | 24 |
Vdc |
Output (sensing range) |
1.0 | 4.5 |
Vdc |
Error state (output signal) |
0.0 | 0.75 |
Vdc |
Error state (output signal) |
4.75 | 5.00 |
Vdc |
Power consumption (25°C) |
0.10 | 0.15 |
A |
Response time (T90) |
— |
5 |
Sec. |
Recovery time (T10) |
— |
5 |
Sec. |
Environmental Conditions: |
|
|
|
Ambient temperature |
-20 | 80 |
°C |
Relative humidity |
5 | 95 |
%R.H. |
Linear flow rate |
0.02 | 5.00 | m/sA |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)