Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector - IRC-A1
• Range: 0-5000ppm, 0-5%vol, 0-20%vol, 0-100%vol
• FS Resolution: 15ppm, 100ppm, 500ppm, 0.5%vol
• Accuracy: 1%FS, 1.5%FS, 2.5%FS, 4%FS
• Response Time (t90): < 40s @ 20°C ambient
• MTBF: > 5 years
• Operating Temperature Range: -20°C to +50°C
• Humidity Range: 0 to 95%rh non-condensing
- Quantity:
- - +
Product Specification
IRC-A1 Infrared Carbon Dioxide (CO2) Sensor Description
Alphasense CO2 and Methane infrared sensors are supplied in the industry standard miniature (20mm diameter) gas sensor housing.
Patented optics give the best signal to noise ratio of any 20mm diameter NDIR and universal linearisation constants allow easy implementation.
The on-board temperature sensor allows for software compensation, including ideal gas law correction.
CO2
The IRC-A1 with dual channel pyroelectric detector. This CO2 sensor is designed for IAQ, safety, combustion and high CO2 process control applications.
Application notes explain linearisation, temperature compensation and circuitry.
The IRC-A1 cover the entire concentration range of measurement, simply implement the appropriate linearisation constants in software for your required range:
IAQ |
0 to 5,000ppm CO2 |
Safety |
0 to 5% CO2 |
Combustion |
0 to 20% CO2 |
Process control |
0 to 100% CO2 |
IRC-A1 Infrared Carbon Dioxide Sensor CO2 sensor PERFORMANCE |
|
Maximum Power Requirements |
5.0 VDC, 60mA max. (50% duty cycle source drive) |
Minimum Operating Voltage |
2.0 VDC, 20mA max. (50% duty cycle source drive) |
Source Drive Frequency |
1.5 to 3 Hz (recommended 2 to 2.25 Hz) |
Active Output in N2 (peak-to-peak) |
60 - 100mV @ 2.1 Hz, 50% duty cycle |
Reference Output in N2 (peak-to-peak) |
40 - 80mV @ 2.1 Hz, 50% duty cycle |
Response Time (t90) |
< 40s @ 20°C ambient |
Warm-up Time |
To final zero ± 100ppm < 30 s @ 20°C |
To specification < 30 minutes @ 20°C |
|
|
|
IRC-A1 Infrared Carbon Dioxide Sensor CO2 sensor LIFETIME |
|
MTBF |
> 5 years |
|
|
IRC-A1 Infrared Carbon Dioxide Sensor CO2 sensor KEY SPECIFICATIONS |
|
Temperature Signal |
Integral thermistor (NTC, R25 = 3000Ω Β= 3450K) |
Operating Temperature Range |
-20°C to +50°C (linear compensation from -10 to 40°C) |
Storage Temperature Range |
-40°C to +75°C |
Humidity Range |
0 to 95%rh non-condensing |
TYPE* |
Range (Application) |
Accuracy (%FS, using universal linearisation coefficients) |
Zero Resolution |
Full Scale Resolution |
Zero Repeatability |
Full Scale Repeatability |
IAQ |
0 to 5000ppm (IAQ) |
1 |
1ppm |
15ppm |
±10ppm |
±50ppm |
Other |
0 to 5 % vol (Safety) |
1.5 |
1ppm |
100ppm |
±10ppm |
±500ppm |
0 to 20 % vol (Combustion) |
2.5 |
1ppm |
500ppm |
±10ppm |
±2500ppm |
|
0 to 100 % vol (Process Control) |
4 |
1ppm |
0.5 % vol |
±10ppm |
±5000ppm |
Matched Transmitter board for IRC-A1 Infrared CO2 Sensor
IRC-TX NDIR CO2 Transmitter Board Features
• Both 4-20mA and USB output
• Uses Alphasense IRC-A1 NDIR cell
• Adjustable bulb voltage to optimise long-term stability vs. resolution
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Fast Response NDIR CO2 Sensor Carbon Dioxide Sensor