Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor - MisIR
• Low Power 20mW
• Measurement ranges from 0 to 1%
• Low noise measurement (<10ppm)
• 3.3V to 5V supply.
• Digital (UART)and Voltage Output Options
• Automatic calibration
• Operating Conditions: 0°C to 50°C; 0 to 95%RH non-condensing
• Accuracy: ±50 ppm +/- 3% of reading
- Quantity:
- - +
Product Specification
MisIR Carbon Dioxide Sensor NDIR CO2 Sensor Summary
NDIR CO2 Sensor MisIR is a low power (20mW), high
performance CO2 sensor. Based on GSS patented solid state IR sensor
technology and innovative optical designs, MISIR is configured to meet
the requirements of the HVAC and Demand Led Ventilation markets.
MisIR Carbon Dioxide Sensor NDIR CO2 Sensor Characteristic
• Low Power 20mW
• Measurement ranges from 0 to 1%
• Low noise measurement (<10ppm)
• 3.3V to 5V supply.
• Digital (UART)and Voltage Output Options
• Automatic calibration
MisIR Carbon Dioxide Sensor NDIR CO2 Sensor Specification
General Performance |
|
Warm-up Time |
< 20 seconds |
Operating Conditions |
0°C to 50°C 0 to 95% RH, non-condensing |
Recommended Storage |
-30°C to +70°C |
CO2 Measurement |
|
Sensing Method |
Non-dispersive infrared (NDIR) absorption Patented Gold-plated optics, GSS Solid-state source and detector |
Sample Method |
Diffusion |
Measurement Range |
0-2000ppm, 0-5000ppm, 0-1% |
Accuracy |
±50 ppm +/- 3% of reading |
Non Linearity |
< 1% of FS |
Calibration |
Automatic Calibration |
Pressure Dependence |
0.13% of reading per mm Hg in normal atmospheric conditions |
Operating Pressure Range |
950 mbar to 1100 bar |
Response Time |
2 minutes |
Electrical/ Mechanical |
|
Power Input |
3.25 to 5.25V. (3.3V recommended). Peak Current 150mA3. Average Current 6mA3. |
Power Consumption |
20 mW |
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor MisIRDimensions and Wiring Connections
The total height is 15mm at the highest point.
Pin |
Description |
Comment |
PWR |
Vsupply |
3V3 to 5.25V |
GND |
0V |
Only one GND pin should be connected. |
Rx |
Sensor receive line (UART) |
5V Tolerant |
Tx |
Sensor transmit line (UART) |
Voh = Vsupply |
Vout |
Voltage Output |
Vout proportional to CO2 concentration. Full scale = Vsupply
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Fast Response NDIR CO2 Sensor Carbon Dioxide Sensor