Fast Response NDIR CO2 Sensor Carbon Dioxide Sensor - SprintIR-6S
• Measurement range: 0-5%, 0-20%, 0-100%
• Accuracy: ±70ppm / ±5% of reading
• Supply voltage: 3.25 - 5.5V DC (3.3V recommended)
• Power consumption: 35mW
• Output type: 3.3V TTL level UART
• Storage Temperature: -30°C to +70°C
• Humidity: 0 - 95% Rh, non-condensing
• Start-up time: < 30 seconds
• Update rate: 20Hz
- Quantity:
- - +
Product Specification
SprintIR-6S Fast Response CO2 Sensor - The Leading NDIR CO2 Sensor
The Ultra fast response CO2 sensors with 6 times faster response rate than the current SprintIR-W is ideal for high speed applications. The SprintIR-6S has response rates that go unmatched by any other NDIR CO2 sensor.
SprintIR-6S Fast Response CO2 Sensor is designed for applications that require capture of rapidly changing CO2 concentrations, and is suitable for measuring concentrations from 0-100%. The sensor takes up to 20 readings per second, and has a 6 times faster response rate than the current SprintIR CO2 sensor, making it the world’s fastest battery-powered NDIR CO2 sensor. This is achieved by using a small sample volume of only 2ml.
SprintIR-6S NDIR CO2 Sensor Carbon Dioxide Sensor Features
• Low power / energy consumption - 35mW
• Measures up to 100% CO2 concentration
• Ultra-fast response rate; 6X faster than the SprintIR a
• High speed sensing; 20 measurements per second (20Hz)
• Sample volume of only 2ml
• Solid-state; no moving parts, no heated filaments
• Digital (UART) output
SprintIR-6S NDIR CO2 Sensor Carbon Dioxide Sensor Benefits
• Very fast response
• Ideal for very low power and battery applications
• Suitable for wireless, portable, wearable and self-powered systems
• Fits neatly inside compact instruments
SprintIR-6S NDIR CO2 Sensor Carbon Dioxide Sensor Specifications
Technical Specifications |
|
Supply voltage |
3.25 - 5.5V DC (3.3V recommended) |
Current |
<15mA (average) 100mA Peak |
Power consumption |
35mW |
Output type |
3.3V TTL level UART |
Operating Temperature |
0°C to +50°C (standard) -25°C to +55°C (extended) |
Storage Temperature |
-30°C to +70°C |
Humidity |
0 - 95% Rh, non-condensing |
Start-up time |
< 30 seconds |
CO2 Measurement Specifications |
|
Sensing method |
Non-dispersive infrared (NDIR) absorption |
Sample method |
Flow through adaptor |
Measurement range |
0-5%, 0-20%, 0-100% |
Accuracy |
±70ppm / ±5% of reading (100% range ±300ppm ±5% of reading) |
Measurement noise |
<10% of reading (no digital filtering) |
Pressure dependence |
0.15% of reading per mbar in normal atmospheric conditions |
Operating pressure range |
500mbar to 2 bar with flow through adaptor |
Response time (a step to change in gas level) |
Flow rate dependant; refer to graph overleaf |
Update rate |
20Hz |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector