Nitric Oxide Sensor (NO Sensor) - NO-A1
• Range: 250 ppm NO limit of performance warranty
• Sensitivity: 320 to 480 nA/ppm in 50ppm NO
• Response time t90: < 45s from zero to 50ppm NO
• Resolution: < 0.2 RMS noise (ppm equivalent)
• Temperature range: -30 to 50°C
• Pressure range: 80 to 120 kPa
• Humidity range: 15 to 90 % rh continuous
• Weight: < 6 g
- Quantity:
- - +
Product Specification
NO-A1 Nitric Oxide Sensor (NO Sensor) Description
Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology.
NO-A1 Nitric Oxide Sensor size:
20mm diameter, the industry standard size for portable gas detectors
The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers.
Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes.
The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.
NO-A1 Nitric Oxide Sensor NO sensor Schematic Diagram
NO-A1 Nitric Oxide Sensor NO sensor PERFORMANCE |
||
Sensitivity |
nA/ppm in 50ppm NO |
320 to 480 |
Response time |
t90 (s) from zero to 50ppm NO |
< 45 |
Zero current |
ppm equivalent in zero air |
0 to +2 |
Resolution |
RMS noise (ppm equivalent) |
< 0.2 |
Range |
ppm NO limit of performance warranty |
250 |
Linearity |
ppm error at full scale, linear at zero and 50ppm NO |
+15 to +25 |
Overgas limit |
maximum ppm for stable response to gas pulse |
800 |
|
|
|
NO-A1 Nitric Oxide Sensor NO sensor LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
< 0.3 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 5 |
Operating life |
months until 80% original signal (24 month warranted) |
> 24 |
|
|
|
NO-A1 Nitric Oxide Sensor NO sensor ENVIRONMENTAL |
||
Sensitivity @ -20°C |
% (output @ -20°C/output @ 20°C) @ 50ppm |
83 to 94 |
Sensitivity @ 50°C |
% (output @ 50°C/output @ 20°C) @ 50ppm |
98 to 104 |
Zero @ -20°C |
ppm equivalent change from 20°C |
< 0 to -1 |
Zero @ 50°C |
ppm equivalent change from 20°C |
< 3 to 16 |
|
|
|
NO-A1 Nitric Oxide Sensor NO sensor CROSS SENSITIVITY |
||
H2S sensitivity |
% measured gas @ 20ppm H2S |
< 30 |
NO2 sensitivity |
% measured gas @ 50ppm NO2 |
< 5 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< 15 |
SO2 sensitivity |
% measured gas @ 20ppm SO2 |
< 3 |
H2 sensitivity |
% measured gas @ 400ppm H2 |
< 0.1 |
CO sensitivity |
% measured gas @ 400ppm CO |
< 0.1 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 0.1 |
CO2 sensitivity |
% measured gas @ 5% Vol CO2 |
< 0.1 |
|
|
|
NO-A1 Nitric Oxide Sensor NO sensor KEY SPECIFICATIONS |
||
Bias voltage |
mV (working electrode potential is above ground) |
+300 |
Temperature range |
°C |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
% rh continuous |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (recommended) |
10 to 47 |
Weight |
g |
< 6 |
Matched Transmitter board for NO-A1 NO Sensor
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)
-
Electrochemical Carbon Monoxide (CO) Sensor 0-1000ppm