Carbon Monoxide (CO) Gas Sensor - MICROceL CF
• Operating Principle: 3-electrode electrochemical
• Measurement Range: 0-500 ppm CO
• Sensitivity: 0.045 ± 0.01 µA/ppm
• T50 Response Time: <10 Seconds at 20°C
• Linearity: Linear up to 1500 ppm CO
• Operating Temperature Range: -40°C to +50°C
- Quantity:
- - +
Product Specification
MICROceL CF Carbon Monoxide Sensor (CO sensor) Description
MICRO 3-electrode carbon monoxide sensor with inboard filter.
• A robust carbon monoxide sensor suitable for portable life safety applications
• Extremely small size
MICROceL CF Carbon Monoxide Sensor (CO sensor) Technical Specifications
MEASUREMENT |
|
Operating Principle |
3-electrode electrochemical |
Measurement Range |
0-500 ppm CO |
Maximum Overload |
1500 ppm CO |
Filter |
To remove TLV levels of interfering gases |
Sensitivity* |
0.045 ± 0.01 µA/ppm |
T50 Response Time |
<10 Seconds at 20°C |
Typical T90 Response Time |
15 to 20 seconds |
Baseline Offset (clean air) |
-4 to +2 ppm CO equivalent |
Maximum Zero Shift* (+20°C to +40°C) |
2 ppm CO equivalent |
Linearity |
Linear up to 1500 ppm CO |
|
|
ELECTRICAL |
|
Recommended Load Resistor |
10 Ω |
Bias Voltage |
Not Required |
|
|
MECHANICAL |
|
Weight |
1.2 g |
Housing Material |
ABS |
Orientation |
Any |
|
|
ENVIRONMENTAL |
|
Operating Temperature Range |
-40°C to +50°C |
Recommended Storage Temp |
0°C to 20°C |
Operating Pressure Range |
Atmospheric ± 10% |
Operating Humidity Range |
15 - 90% RH non-condensing |
|
|
LIFETIME |
|
Expected Operating Life |
Two years in air |
Long Term Output Drift |
<5% signal loss per year |
Storage Life |
6 months in CTL container |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)