UV Sensor Probe - GUVx-T1xGC-I8LW5.1
- Water Environment (<10 bar)
- Single Supply Voltage, 4-20mA Current Output
- Operating Temperature: -30~85°C
- Supply Voltage: 9~24 VDC
- Output Current: 4 ~ 20 mA
- Detection Range:
GUVV-T11GC-I8LW5.1: 230~395nm
GUVB-T12GC-I8LW5.1: 220~320nm
GUVC-T11GC-I8LW5.1: 220~280nm
- Quantity:
- - +
Product Specification
GUVx-T1xGC-I8LW5.1 UV Sensor Probe Feature
- Water Environment (<10 bar)
- Single Supply Voltage, 4-20mA Current Output
GUVx-T1xGC-I8LW5.1 UV Sensor Probe Application
- UV Power Measure
- UV Lamp Monitoring
GUVx-T1xGC-I8LW5.1 UV Sensor Probe Case dimensions
Thread/Length for Mounting |
Diameter (mm) |
Window
(mm) |
Wrench
Size (mm) |
Length
(mm) |
Weight (g) |
Body
(stainless steel) |
FT1/4 "/12 mm | 21 |
7 |
19 | 63 |
67 |
316L (1.4404) |
GUVx-T1xGC-I8LW5.1 UV Sensor Probe Absolute Maximum Ratings
Parameter |
Symbol |
Min. |
Typ. |
Max. |
Unit |
Remark |
Storage Temperature |
Tst |
-40 |
|
90 |
°C |
|
Operating Temperature |
Top |
-30 |
|
85 |
°C |
|
GUVx-T1xGC-I8LW5.1 UV Sensor Probe Electro-Optical Characteristics (at 25°C)
Parameter |
Symbol |
Min. |
Typ. |
Max. |
Unit |
Remark |
|
Supply Voltage |
Vcc |
9 |
|
24 | V |
DC |
|
Offset Current |
Ioff |
3.9 | 4.0 | 4.1 | mA |
|
|
Detection Range |
GUVV-T11GC-I8LW5.1 |
λ |
230 |
|
395 | nm |
10% of Max |
GUVB-T12GC-I8LW5.1 |
λ |
220 |
|
320 |
nm |
10% of Max |
|
GUVC-T11GC-I8LW5.1 |
λ |
220 |
|
280 |
nm |
10% of Max |
|
Output Current |
Iout |
4 |
|
20 | mA |
|
|
Detection Power Range |
P | 0 |
|
100 | mW/cm2 |
|
|
Response Time |
T |
|
10 |
|
ms |
|
* Maximum of detection power : 20mW/cm2 (Option), 100mW/cm2 (Standard), 1000mW/cm2 (Option)
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service