UV Sensor Probe - GUVx-T1xGC-2LA5

  • UV Sensor Probe
  • UV Sensor Probe
Mouse over image to zoom

- Air Environment
- Single Supply Voltage, Analog Voltage Output
- Case dimensions: 36 x 30 x 16mm
- Power supply: 9~24V, Supply Current: 3.3mA
- Output: DC voltage(0~5V)
- Detection Range:
GUVV-T10GC-2LA5 : 230~395nm
GUVB-T11GC-2LA5 : 220~320nm
GUVC-T10GC-2LA5 : 220~280nm

  • Model Number: GUVx-T1xGC-2LA5
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

GUVx-T1xGC-2LA5 UV Sensor Probe Features
- Single Supply Voltage, Analog Voltage Output
- Air Environment

GUVx-T1xGC-2LA5 UV Sensor Probe Applications
- UV Power Measurement
- UV Lamp, LED Monitoring

GUVx-T1xGC-2LA5 UV Sensor Probe Absolute Maximum Ratings

Parameter
Symbol
Value
Unit
Remark
Min.
 Typ.
 Max
Storage Temperature
Tst
-40
90 °C

Operating Temperature
Top
-30
85 °C


GUVx-T1xGC-2LA5 UV Sensor Probe Electro-Optical Characteristics (at 25°C)

Parameter
Symbol
Value
Unit
Remark
Min.
Typ.
Max.
Supply Voltage
Vcc
9
24 V DC
Supply Current
IQ

3.3
mA
Detection Range
GUVV-T10GC-2LA5
λ
230
395 nm 10% of Max
GUVB-T11GC-2LA5
λ
220
320 nm 10% of Max
GUVC-T10GC-2LA5
λ
220
280 nm 10% of Max
Output Voltage
Vout
0
5 V
Detection Power Range
P 0
100 mW/cm2
Response Time
T
10
ms

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service