UV Sensor Probe - GUVx-T1xGC-2LA5
- Air Environment
- Single Supply Voltage, Analog Voltage Output
- Case dimensions: 36 x 30 x 16mm
- Power supply: 9~24V, Supply Current: 3.3mA
- Output: DC voltage(0~5V)
- Detection Range:
GUVV-T10GC-2LA5 : 230~395nm
GUVB-T11GC-2LA5 : 220~320nm
GUVC-T10GC-2LA5 : 220~280nm
- Quantity:
- - +
Product Specification
GUVx-T1xGC-2LA5 UV Sensor Probe Features
- Single Supply Voltage, Analog Voltage Output
- Air Environment
GUVx-T1xGC-2LA5 UV Sensor Probe Applications
- UV Power Measurement
- UV Lamp, LED Monitoring
GUVx-T1xGC-2LA5 UV Sensor Probe Absolute Maximum Ratings
Parameter |
Symbol |
Value |
Unit |
Remark |
||
Min. |
Typ. |
Max |
||||
Storage Temperature |
Tst |
-40 |
|
90 |
°C |
|
Operating Temperature |
Top |
-30 |
|
85 |
°C |
|
GUVx-T1xGC-2LA5 UV Sensor Probe Electro-Optical Characteristics (at 25°C)
Parameter |
Symbol |
Value |
Unit |
Remark |
|||
Min. |
Typ. |
Max. |
|||||
Supply Voltage |
Vcc |
9 |
|
24 | V | DC | |
Supply Current |
IQ |
|
3.3 |
|
mA |
|
|
Detection Range |
GUVV-T10GC-2LA5 |
λ |
230 |
|
395 | nm |
10% of Max |
GUVB-T11GC-2LA5 |
λ |
220 |
|
320 | nm |
10% of Max |
|
GUVC-T10GC-2LA5 |
λ |
220 |
|
280 | nm |
10% of Max |
|
Output Voltage |
Vout |
0 |
|
5 | V |
|
|
Detection Power Range |
P | 0 |
|
100 | mW/cm2 |
|
|
Response Time |
T |
|
10 |
|
ms |
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service