UV Sensor Probe - GUVx-T1xGC-LA2
- Single Supply Voltage, Analog Voltage Output
- Supply Voltage: 1.8 - 5.5VDC
- Supply Current: 0.05mA
- Output Voltage: 0-5V
- Detection Power Range: 0~100mW/cm2
- Detection Range:
GUVV-T10GC-LA2: 230 - 395nm
GUVB-T11GC-LA2: 220 - 320 nm
GUVC-T10GC-LA2: 220 - 280 nm
- Quantity:
- - +
Product Specification
GUVx-T1xGC-LA2 UV Sensor Probe Features
- Air Environment, Single Supply Voltage, Analog Voltage Output
GUVx-T1xGC-LA2 UV Sensor Probe Applications
- UV Lamp Monitoring
GUVx-T1xGC-LA2 UV Sensor Probe Absolute Maximum Ratings
Parameter |
Symbol |
Value |
Unit |
Remark |
||
Min. |
Typ. |
Max |
||||
Storage Temperature |
Tst |
-40 |
|
90 |
℃ |
|
Operating Temperature |
Top |
-30 |
|
85 |
℃ |
|
GUVx-T1xGC-LA2 UV Sensor Probe Electro-Optical Characteristics (at 25 ℃)
Parameter |
Symbol |
Value |
Unit |
Remark |
|||
Min. |
Typ. |
Max. |
|||||
Supply Voltage |
Vcc |
1.8 | 5 | 5.5 | V | DC | |
Supply Current |
IQ |
|
0.05 |
|
mA |
|
|
Detection
Range |
GUVV-T10GC-LA2 |
λ |
230 |
|
395 | nm |
10% of Max |
GUVB-T11GC-LA2 |
λ |
220 |
|
320 | nm |
10% of Max |
|
GUVC-T10GC-LA2 |
λ |
220 |
|
280 | nm |
10% of Max |
|
Output Voltage |
Vout |
0 |
|
5 | V |
Vcc=5V |
|
Detection Power Range |
P | 0 |
|
100 | mW/cm2 |
Vcc=5V |
|
Response Time |
T |
|
10 |
|
ms |
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service