UV Sensor Probe - GUVA-S12SC-3LWH3
- Single Supply Voltage
- Analog Voltage Output
- UV Power Monitoring of Sunlight
- Supply Current: 3.3mA
- Response Time: 10ms
- Output Voltage: 0.1V
- Spectral Detection Range: 240-370nm
- Quantity:
- - +
Product Specification
GUVA-S12SC-3LWH3 UV Sensor Probe Features
- Single Supply Voltage, Analog Voltage Output
- Measure the UV Power from Sunlight
GUVA-S12SC-3LWH3 UV Sensor Probe Applications
- UV Power Monitoring of Sunlight
GUVA-S12SC-3LWH3 UV Sensor Probe Absolute Maximum Ratings
Parameter |
Symbol |
Value |
Unit |
Remark |
||
Min. |
Typ. |
Max |
||||
Storage Temperature |
Tst |
-40 |
|
90 |
℃ |
|
Operating Temperature |
Top |
-30 |
|
85 |
℃ |
|
GUVA-S12SC-3LWH3 UV Sensor Probe Electro-Optical Characteristics (at 25 ℃)
Parameter |
Symbol |
Value |
Unit |
Remark |
|||
Min. |
Typ. |
Max. |
|||||
Supply Voltage |
Vcc |
9 |
|
24 | V | Standard | |
1.8 |
|
5.5 | V |
Low Power (Option) |
|||
Supply Current |
IQ |
|
3.3 |
|
mA |
|
|
Spectral Detection Range |
λ |
240 |
|
370 | nm |
10% of Max |
|
Output Voltage |
Vout |
|
0.1 |
|
V |
at 1 mW/cm2 |
|
Response Time |
T |
|
10 |
|
ms |
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click: