UV Sensor Probe - GUVx-T1xGC-5LW9

  • UV Sensor Probe
  • UV Sensor Probe
Mouse over image to zoom

- AlGaInN-based UV Sensor
- Single Supply Voltage, Analog Voltage Output
- Water Environment (10 bar)
- Supply Voltage: DC 5V
- Supply Current: 0.05mA
- Output voltage : 0 ~ 5 V
- Detection Range:
GUVA-T11GC-5LW9: 220~370nm
GUVC-T10GC-5LW9: 220~280nm

  • Model Number: GUVx-T1xGC-5LW9
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

GUVx-T1xGC-5LW9 UV Sensor Probe Feature
- Single Supply Voltage, Analog Voltage Output, Cable length : 1m
- Water Environment (10 bar)

GUVx-T1xGC-5LW9 UV Sensor Probe Application
- UV Curing Lamp Monitoring
- Sterilization Lamp Monitoring


GUVx-T1xGC-5LW9 UV Sensor Probe Absolute Maximum Ratings
Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Storage Temperature
Tst
-40
90 °C

 Operating Temperature
Top
-30
85 °C


GUVx-T1xGC-5LW9 UV Sensor Probe Electro-Optical Characteristics (at 25°C)

Parameter
Symbol
Min.
Typ.
Max.
Unit
Remark
Supply Voltage
Vcc

5
V DC
Supply Current
IQ

0.05
mA
Detection Range
GUVA-T11GC-5LW9 λ
220
370 nm 10% of Max
GUVC-T10GC-5LW9
λ
220
280 nm
10% of Max
Output Voltage
Vout
0
5 V
Detection Power Range
P 0
20 mW/cm2
Response Time
T
10
ms

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service