UV Sensor Probe - GUVC-T11GC-DVGW
- Case Material: SUS 316-L(1.4404)
- Water Environment (10 bar)
- AlGaInN-based UV Sensor
- Supply Voltage: DC 24 V
- Offset Current: 4mA
- Spectral Detection Range: 220~280nm
- 2 wire 4-20 mA Current Output
- Detection Power Range: 0 ~ 100 ㎽/㎠
- Quantity:
- - +
Product Specification
GUVC-T11GC-DVGW UV Sensor Probe Features
- Single Supply Voltage, 2 wire 4-20 mA Current Output
- Water Environment (10 bar)
- UV sensor Probe complies with the standard DVGW W294-3(2006)
GUVC-T11GC-DVGW UV Sensor Probe Applications
- Sterilization Lamp Monitoring
- Pure UV-C Monitoring
GUVC-T11GC-DVGW UV Sensor Probe (Measuring window tube) Dimensions
Thread/Length for probe hold |
Diameter (mm) |
Window (mm) |
Depth (mm) |
Length (mm) |
Weight (g) |
Body (stainless steel) |
G 1" / 34 mm | 32 |
24 |
59 | 94 |
660 |
316-L ( 1.4404 ) |
GUVC-T11GC-DVGW UV Sensor Probe (Sensor shaft) Dimensions
Thread/Length for probe hold |
Diameter (mm) |
Window (mm) |
Depth(mm) |
Length (mm) |
Weight (g) |
Body (stainless steel) |
-- | 20 | 16 | 66 | 83 | 120 |
316-L ( 1.4404 ) |
GUVC-T11GC-DVGW UV Sensor Probe Absolute Maximum Ratings
Parameter |
Symbol |
Value |
Unit |
Remark |
||
Min. |
Typ. |
Max. | ||||
Storage Temperature |
Tst |
-40 |
|
90 |
°C |
|
Operating Temperature |
Top |
-30 |
|
85 |
°C |
|
GUVC-T11GC-DVGW UV Sensor Probe Electro-Optical Characteristics (at 25°C)
Parameter |
Symbol |
Value |
Unit |
Remark | ||
Min. |
Typ. |
Max. |
||||
Supply Voltage |
Vcc |
|
24 |
|
V |
DC |
Offset Current |
Ioff |
|
4 |
|
mA |
|
Spectral Detection Range |
λ |
220 |
|
280 | nm |
10% of Max |
Output Current |
Iout |
4 |
|
20 | mA |
|
Detection Power Range |
P | 0 |
|
100 | mW/cm2 |
Vcc = 24 V |
Response Time |
T |
|
5 |
|
ms |
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service