UV-C Sensor Probe - GUVC-T11GC-4LW11

  • UV-C Sensor Probe
  • UV-C Sensor Probe
Mouse over image to zoom

- Water Environment (10 bar)
- Single Supply Voltage, Analog Voltage Output
- AlGaInN-based UV Sensor
- Thread/Length for Mounting:PT 1¼ " /21 mm
- Supply Voltage: DC 9~24 V
- Supply Current: 3.3mA
- Output DC voltage: 0 ~ 5 V
- Spectral Detection Range: 220~280nm

  • Model Number: GUVC-T11GC-4LW11
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

GUVC-T11GC-4LW11 UV Sensor Probe Features
 - Single Supply Voltage, Analog Voltage Output
 - Water Environment (10 bar)

GUVC-T11GC-4LW11 UV Sensor Probe Applications
 - Sterilization Lamp Monitoring
 - Pure UV-C Monitoring

GUVC-T11GC-4LW11 UV Sensor Probe Case dimensions

Thread/Length for Mounting
Body (mm)
 Window (mm)
Head (mm)
Wrench Size (mm)
Length (mm)
Weight (kg)
Body (stainless steel)
PT 1¼ "/21 mm Φ42 Φ24 x 24
Φ36 x 15 36 81 0.44
316-L ( 1.4404 )

GUVC-T11GC-4LW11 UV Sensor Probe Absolute Maximum Ratings
Parameter
Symbol
Value
Unit
Remark
Min.
Typ.
Max.
Storage Temperature
Tst
-40
90 °C

 Operating Temperature
Top
-30
85 °C


GUVC-T11GC-4LW11 UV Sensor Probe Electro-Optical Characteristics (at 25°C)

Parameter
Symbol
Value
Unit
Remark
Min.
Typ.
Max.
Supply Voltage
Vcc
9
24 V DC
Supply Current
IQ

3.3
mA
Spectral Detection Range
λ
220
280 nm 10% of Max
Output Voltage
Vout
0
5 V
Detection Power Range
P 0
100 mW/cm2 Total power of 4 sensor
Response Time
T
10
ms
* Maximum of detection power : 20 mW/cm2 (Option), 100 mW/cm(Standard)


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service