NDIR Methane (CH4) Gas Sensor - IRceL CH4
• Operating Principle: Non-Dispersive Infra-Red
• Measurement Range: 0-5% vol. Methane
• Accuracy (-20°C to +50°C): Within ± (0.1% vol CH 4 + 4% of concentration)
• Response Time (T90): < 35 Seconds
• Supply Voltage: 3-5 VDC, 3.3 V to utilise EEPROM calibration
• MTBF: > 5 years
- Quantity:
- - +
Product Specification
IRceL CH4 NDIR CH4 Sensor Description
Miniature infrared sensor with on-board EEPROM and thermistor
IRceL CH4 NDIR CH4 Sensor Key Features & Benefits:
• Integrated thermistor for accurate temperature compensation
• EEPROM programmed with sensor specfic performance characteristics
• Compact Size
IRceL CH4 NDIR CH4 Sensor Technical Specifications
MEASUREMENT |
|
Operating Principle |
Non-Dispersive Infra-Red (NDIR) |
Measurement Range |
0-5% vol. Methane |
Accuracy (-20°C to +50°C) |
Within ± (0.1% vol CH 4 + 4% of concentration) |
Response Time (T90) |
< 35 Seconds |
Repeatability: Zero 5% CH |
< ±0.015% CH 4 < ±0.05% CH |
Linearity |
See Operating Principles OP17 |
|
|
ELECTRICAL |
|
Supply Voltage |
3-5 VDC, 3.3 V to utilise EEPROM calibration |
Power Consumption |
<100 mW at 3.3 V |
Recommended Lamp Frequency |
2 Hz, 50% duty cycle |
Minimum Resolution |
0.03% CH 4 at zero 0.1% CH 4 at range |
Warm-up Time |
< 10 Seconds |
|
|
MECHANICAL |
|
Housing Material |
Stainless Steel (see back page) |
Weight |
23 g |
Orientation |
Any |
|
|
ENVIRONMENTAL |
|
Typical Applications |
General Purpose Portable Fixed Methane Detection |
Operating Temperature Range |
-20°C to +50°C |
Operating Humidity Range |
0 to 99% RH (non-condensing) |
Operating Pressure Range |
700 to 1300 mBar with compensation |
|
|
LIFETIME |
|
Long Term Zero Drift |
< ±0.05% CH 4 per month |
Recommended Storage Temp |
-20°C to +50°C |
MTBF |
> 5 years |
Standard Warranty |
12 months from date of despatch |
IMPORTANT NOTE:
Connection should be made via PCB sockets only. Soldering to the pins will seriously damage your sensor.
All performance data is based on conditions at 20°C, 50%RH and 1013mBar, using City Technology recommended circuitry. For sensor performance data under other conditions, refer to the Characterisation Note and Operating Principles.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector