NDIR CO2 Sensor Module for Environment Parameters Logging - CO2 Engine BLG
▪ Measurement range CO2: 0 to 30%vol(CO2)
▪ Measurement range RH: 0 to 100%
▪ Measurement range °C: -40 to 60
▪ Low power consumption
▪ Individually calibrated
▪ Maintenance-free
▪ High quality
- Quantity:
- - +
Product Specification
CO2 Engine BLG
Sensor module for environment parameters logging
CO2 Engine BLG NDIR CO2 Sensor Modules General
▪ This document describes a family of sensor modules CO2 Engine BLG designed to measure and store records of environmental parameters such as
- Temperature
- Relative Humidity
- CO2 concentration (up to 30% range).
▪ The sensor module CO2 Engine BLG is designed for battery powered operation with low average power consumption without compromising measurement precision and resolution.
▪ Virtual RTC (Real Time Clock) allows data and events logging with time stamps.
▪ Events include sensor power on, logging start/stop, ABC self calibration, user initiated zero and background calibrations.
▪ Reading of logger via I2C connector and SenseAir's I2C - USB bridge (SADK).
▪ I2C or UART communication can be used to read logged data for built in modules.
CO2 Engine BLG NDIR CO2 Sensor Modules Applications
The sensor can be used in a wide range of applications such as in food transportation, storage, incubators and other high range applications.
CO2 Engine BLG NDIR CO2 Sensor Modules Technical specification
Item |
CO2 Engine BLG Art. no:. 033-9-0015 |
General performance |
|
Storage temperature range |
-40 to +70 °C |
Storage Environment |
Non condensing, non corrosive environment 1 |
Operating Temperature Range |
0 to 50 °C |
Operating Humidity Range |
0 to 95% RH (non-condensing) 2 |
Operating Environment |
Non corrosive environment 2 . Residential, commercial, industrial spaces used in HVAC (Heating Ventilation and Air- Conditioning) systems 3 |
Sensor Life Expectancy |
> 10 years |
Maintenance Interval |
Maintenance-free. See discussion of ABC algorithm on page 10 |
Self-Diagnostics |
complete function check of the sensor module |
Conformance with standards |
RoHS directive 2011/65/EU |
Electrical / Mechanical |
|
Power Input |
4.75-12 VDC 4 max rating, stabilized to within 10% powering sensor via Vbat+ 5.5-12 VDC 4 max rating, stabilized to within 10% powering sensor via G+ (on board protection circuits) |
Current consumption |
~250μA (1 measurement/hour) ~50μA in sleep ~60 mA average during active measurement sequence (~12s) < 150 mA peak current (averaged during IR lamp ON, 100 msec) < 250 mA peak power (during IR lamp start-up, the first 50 msec) for maximum operating time (if powered by batteries), choose batteries that can deliver 250mA pulses without large voltage drops (for example batteries recommended for cameras) |
Electrical connections |
Vbat+, G+ and G0 |
Dimensions (mm) |
51 x 57 x 14 mm (Length x Width x Height) (0..30% measurement range) |
CO2 measurement |
|
Sensing Method |
non-dispersive infrared (NDIR) waveguide technology with ABC, automatic background calibration algorithm (application specific) |
Sampling Method |
diffusion |
Response Time (T1/e) |
<25 sec gas diffusion time |
Measurement period |
5 min to 0.5 year interval, a measurement period less than 5 min can be used, but then specified accuracy on RH and temperature measurements are not guaranteed |
Repeatability |
± 0,1 %vol. CO 2 ± 2 % of measured value |
Accuracy 5 |
± 0,2 %vol. CO 2 ± 3 % of measured value |
Pressure Dependence |
+ 1.6 % reading per kPa deviation from normal pressure, 100 kPa |
On-board calibration support |
Din1 switch input to trigger Background Calibration @ 400 ppm (0.04%vol) CO2 Din2 switch input to trigger Zero Calibration @ 0 ppm CO2 |
Temperature Measurement |
|
Sensor |
SHT11 from Sensirion |
Measurement Range |
- 40 to 60°C |
Accuracy 6, 7 |
± 0.4°C at 25°C |
Relative Humidity Measurement |
|
Sensor |
SHT11 from Sensirion |
Measurement Range |
0 to 100% RH non condensing |
Accuracy 6, 7 |
± 3% RH |
Logger properties |
|
Logger Capacity |
5400 logging points if CO2 concentration, temperature and relative humidity are logged (with timestamp) |
Logging Data |
Selectable, one data record can contain up to 14 bytes (max 4 variables) |
Logging Period |
(1…255) * Measurement Period |
|
|
Delay since setting jumper |
0 to 255 seconds (5s in default configuration) |
2 Sensors are 100% tested in production at 45C / 85%RH / 1000ppm CO2 for one hour. For applications operating continuously in high humidity, contact SenseAir for further information.
3 Different options exist and can be customized depending on the application. Please, contact SenseAir for further information!
4 Notice that absolute maximum rating is 12V, so sensor can not be used with 12V+-10% supply.
5 Accuracy is specified over operating temperature range at normal pressure 1013 mBar. Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (+-2% currently) is to be added to the specified accuracy for absolute measurements.
6 Specification is provided by Sensirion.
7 Minimum 5 minutes measurement period.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector