Miniature Size Chlorine Sensor (CL2 Sensor) - CL2-D4

  • Miniature Size Chlorine Sensor (CL2 Sensor)
  • Miniature Size Chlorine Sensor (CL2 Sensor)
Mouse over image to zoom

• Range: 20ppm Cl2 limit of performance warranty
• Sensitivity: -200 to -450nA/ppm in 10ppm Cl2
• Response time t90: < 35s from zero to 10ppm Cl2
• Resolution: < 0.1 RMS noise (ppm equivalent)
• Temperature range : -20 to 50°C
• Pressure range: 80 to 120 kPa
• Humidity range: 15 to 90 %rh (see note below)
• Weight: < 2 g

  • Model Number: CL2-D4
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

CL2-D4 Miniature Size Chlorine Sensor (CL2 Sensor) Description
Alphasense Chlorine gas sensors operate using proven fuel cell technology.

CL2-D4 Chlorine Sensor size:
miniature, with proven long-term performance, for the next generation of gas detectors

The Cl2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 20ppb and an operating range from +0 to 20ppm. The sensors are suitable for inclusion in fixed installation sensing heads and portable safety instruments.

These sensors have improved transient response to humidity changes compared to competitors’ equivalent sensors.

The Cl2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.


CL2-D4 Chlorine Sensor (CL2 Sensor) PERFORMANCE
Sensitivity
nA/ppm in 10ppm Cl2
-200 to -450
Response time
t90 (s) from zero to 10ppm Cl2
< 35
Zero current
ppm equivalent in zero air
± 0.8
Resolution
RMS noise (ppm equivalent)
< 0.1
Range
ppm Cl2  limit of performance warranty
20
Linearity
ppm error at full scale, linear at zero and 10ppm Cl2
± 0.5
Overgas limit
maximum ppm for stable response to gas pulse
60



CL2-D4 Chlorine Sensor (CL2 Sensor) LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/month in lab air, twice monthly test
nd
Operating life
months until 80% original signal (24 month warranted)
>24



CL2-D4 Chlorine Sensor (CL2 Sensor) ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 10ppm Cl2
80 to 110
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 10ppm Cl2
95 to 125
Zero @ -20°C
ppm equivalent change from 20°C
-0.4 to 0.4
Zero @ 50°C
ppm equivalent change from 20°C
0 to 0.5



CL2-D4 Chlorine Sensor (CL2 Sensor) CROSS SENSITIVITY
H2S     sensitivity
% measured gas @ 20ppm H2S
< -20
NO2    sensitivity
% measured gas @ 10ppm NO2
< 80
NO      sensitivity
% measured gas @ 50ppm NO
< 0.5
SO2    sensitivity
% measured gas @ 20ppm SO2
< 1
CO      sensitivity
% measured gas @ 400ppm CO
< 0.1
H2      sensitivity
% measured gas @ 400ppm H2
< 0.1
C2H4 sensitivity
% measured gas @ 400ppm C2H4
< 0.1
NH3   sensitivity
% measured gas @ 20ppm NH3
< 0.1



CL2-D4 Chlorine Sensor (CL2 Sensor) KEY SPECIFICATIONS
Temperature range
°C
-20 to 50
Pressure range
kPa 
80 to 120
Humidity range
%rh (see note below)
15 to 90
Storage period
months @ 3 to 20°C (stored in sealed pot)
6
Load resistor
Ω (for optimum performance)
33
Weight
g
< 2


If you cannot find what you want, you can entrust OFweek to source for you. Just click: