Miniature Size Chlorine Sensor (CL2 Sensor) - CL2-D4
• Range: 20ppm Cl2 limit of performance warranty
• Sensitivity: -200 to -450nA/ppm in 10ppm Cl2
• Response time t90: < 35s from zero to 10ppm Cl2
• Resolution: < 0.1 RMS noise (ppm equivalent)
• Temperature range : -20 to 50°C
• Pressure range: 80 to 120 kPa
• Humidity range: 15 to 90 %rh (see note below)
• Weight: < 2 g
- Quantity:
- - +
Product Specification
CL2-D4 Miniature Size Chlorine Sensor (CL2 Sensor) Description
Alphasense Chlorine gas sensors operate using proven fuel cell technology.
CL2-D4 Chlorine Sensor size:
miniature, with proven long-term performance, for the next generation of gas detectors
The Cl2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 20ppb and an operating range from +0 to 20ppm. The sensors are suitable for inclusion in fixed installation sensing heads and portable safety instruments.
These sensors have improved transient response to humidity changes compared to competitors’ equivalent sensors.
The Cl2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification.
CL2-D4 Chlorine Sensor (CL2 Sensor) PERFORMANCE |
||
Sensitivity |
nA/ppm in 10ppm Cl2 |
-200 to -450 |
Response time |
t90 (s) from zero to 10ppm Cl2 |
< 35 |
Zero current |
ppm equivalent in zero air |
± 0.8 |
Resolution |
RMS noise (ppm equivalent) |
< 0.1 |
Range |
ppm Cl2 limit of performance warranty |
20 |
Linearity |
ppm error at full scale, linear at zero and 10ppm Cl2 |
± 0.5 |
Overgas limit |
maximum ppm for stable response to gas pulse |
60 |
|
|
|
CL2-D4 Chlorine Sensor (CL2 Sensor) LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
nd |
Sensitivity drift |
% change/month in lab air, twice monthly test |
nd |
Operating life |
months until 80% original signal (24 month warranted) |
>24 |
|
|
|
CL2-D4 Chlorine Sensor (CL2 Sensor) ENVIRONMENTAL |
||
Sensitivity @ -20°C |
% (output @ -20°C/output @ 20°C) @ 10ppm Cl2 |
80 to 110 |
Sensitivity @ 50°C |
% (output @ 50°C/output @ 20°C) @ 10ppm Cl2 |
95 to 125 |
Zero @ -20°C |
ppm equivalent change from 20°C |
-0.4 to 0.4 |
Zero @ 50°C |
ppm equivalent change from 20°C |
0 to 0.5 |
|
|
|
CL2-D4 Chlorine Sensor (CL2 Sensor) CROSS SENSITIVITY |
||
H2S sensitivity |
% measured gas @ 20ppm H2S |
< -20 |
NO2 sensitivity |
% measured gas @ 10ppm NO2 |
< 80 |
NO sensitivity |
% measured gas @ 50ppm NO |
< 0.5 |
SO2 sensitivity |
% measured gas @ 20ppm SO2 |
< 1 |
CO sensitivity |
% measured gas @ 400ppm CO |
< 0.1 |
H2 sensitivity |
% measured gas @ 400ppm H2 |
< 0.1 |
C2H4 sensitivity |
% measured gas @ 400ppm C2H4 |
< 0.1 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 0.1 |
|
|
|
CL2-D4 Chlorine Sensor (CL2 Sensor) KEY SPECIFICATIONS |
||
Temperature range |
°C |
-20 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
%rh (see note below) |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (for optimum performance) |
33 |
Weight |
g |
< 2 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical CL2 Sensor
-
Chlorine Sensor (CL2 Sensor)
-
Chlorine Sensor (CL2 Sensor)
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Pre-calibrated module for combustible gas
-
Compact CO Sensor
-
15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-