15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802 - IAQ_100 C
• Measurement Range: 0 to 100 ppm (calibrated as CO equivalents)
• Response Time to 90%: < 20 seconds typical
• Sensitivity: 12 +/- 3 nA/ppm (CO equivalents)
• Small Size& Low Profile - 20x20x3 mm
• Easy to Use - Linear Response
• Long Life - 10 years expected life
• Fast Response - < 20 seconds
• ROHS Compliant
- Quantity:
- - +
Product Specification
IAQ_100 C
15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802
IAQ_100 C Indoor Air Quality Sensor Description
IAQ_100 is a Screen Printed ElectroChemical sensor component designed for the broad (non-specific) detection of gases associated with poor air quality: sulfides, alcohols, ammonia, odorous gases, and Carbon Monoxide. This ultra-low power sensor is appropriate for applications in: indoor air monitoring, air purifier controls, early fire detection, HVAC ventilation controls and Smart Homes.
IAQ_100 C Indoor Air Quality Sensor Benefits
• Zero Power Sensor
Sensor Circuit - < 10 uW max
• Cold operation - No Heating required
• Rugged Design - Not poisoned by sulfides, chlorides, NH3
• Stable Response - Not affected by humidity, CO2, N2, Ar, most saturated hydrocarbons, hexane
• Small Size& Low Profile - 20 x 20 x 3 mm
• Sensitive - In the ppm range
• Easy to Use - Linear Response
• Long Life - 10 years expected life
• Fast Response - < 20 seconds
• ROHS Compliant
IAQ_100 C Indoor Air Quality Sensor Applications
• Bad Air Quality Detection
• Indoor Air Monitor
• Air Purifier Controls
• Weather Stations
• Internet of Things
• Smart Homes
• Early Fire Detection
• Leak Detection
• HVAC Ventilation Control
IAQ_100 C Indoor Air Quality Sensor Specifications
Measurement Range | 0 to 100 ppm (calibrated as CO equivalents) |
Response Time to 90% | < 20 seconds typical |
Sensitivity | 12 +/- 3 nA/ppm (CO equivalents) |
Expected Operating Life | > 5 years (10 years @ 23+/-3C; 40+/-10% RH) |
Operating Temperature Range | -10 to 40 C (0 to 40 C continuous) |
Operating Humidity - non-condensing | 0 to 100% RH (15 to 95% continuous) |
Power Consumption | < 50 uW circuit & ambient gas dependent |
Zero Drift (Over Temperature Range) | +/- 2 ppm (CO equivalents) |
Lower Detection Limit | 0.1 ppm CO (depends on the gas & electronics) |
IAQ_100 C Indoor Air Quality Sensor Cross Sensitivity
Gas
ppm
Typical Response (as ppm CO)
Carbon Monoxide
100
100
Hydrogen Sulfide
100
370
Ozone
100
-70
Nitrogen Dioxide
100
-50
Sulfur Dioxide
100
70
Ethanol
100
140
Nitric Oxide (NO)
100
80
Chlorine
100
-50
n-Heptane
100
0
Ammonia
100
1
Methane
100
0
Saturated Hydrocarbons
100
0
This sensor exhibits sensitivity to a wide range of gases. The following table lists the relative response of common gases.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Pre-calibrated module for combustible gas
-
Compact CO Sensor
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Carbon dioxide (CO2) sensor module
-
Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6
-
Thermal Conductivity Sensor for Leak or Pressure Detection
-
Ammonia Sensor (NH3 Sensor)