P-type Metal Oxide VOC Sensor - VOC-MFF, VOC-PFF, VOC-AFF
• VOC-xFF: equipped with a PTFE-based dust/water filter
• Range: 1 to 100ppm
• Operating Temperature Range: -20 to 120°C
• stable baseline
• low humidity sensitivity
• positive response to gases (safer response)
- Quantity:
- - +
Product Specification
P-type Metal Oxide VOC Sensor Description
This sensor is a broadband total VOC detector. When the cost of a PID is not justifiable, this sensor will detect VOCs with 10-50 ppb limit of detection, depending on the VOC.
Unlike common n-type sensors, this metal oxide sensor has a large dynamic range, repeatable response, low humidity response and resistance increases in the presence of most VOCs.
The change in resistance can be converted to an output voltage via a simple electrical circuit. Although the sensor can be used in constant temperature/ voltage mode, best response is achieved when the sensor is cycled between 400°C (sensing temperature) and 525°C (reset temperature).
Developed over many years, our p-type metal oxide gas sensors offer the following benefits:
• stable baseline
• low humidity sensitivity
• positive response to gases (safer response)
Volatile Organic Compounds (VOCs) detection for low cost IAQ applications
Each sensor type can be supplied in three housings:
• TO-5 metal can, the most common format
• Plastic 6-pin housing - frequently used with other metal oxide gas sensors
• Ex housing - stainless steel 316 housing with UL, CSA, ATEX and IECEx approvals, unique for metal oxides, allowing use in hazardous areas without the need for an IS circuit
P-type Metal Oxide VOC Sensor Housing options
Housing |
VOC |
TO-5 metal |
VOC-MFF |
6-pin Plastic |
VOC-PFF |
Ex certified metal |
VOC-AFF |
P-type Metal Oxide VOC Sensor PERFORMANCE |
||
Range |
ppm isobutylene limit of performance warranty |
1 to 100 |
Sensor resistance (Ro) |
kΩ (50% rh, 23 ± 2°C) |
220 ±45 |
Sensor resistance ratio (Rg /Ro x 100%) |
%; Isobutylene @ 10ppm in air |
285 ±30 |
|
|
|
Gas response relationship (Rg /Ro - 1 = Σki x Concn ) |
0.5 +/- 10% (k for isobutylene) |
|
where ki = constant for gas i, n = 1 or 0.5 |
0.5 (n for isobutylene) |
|
|
|
|
Heater resistance (RH@ RT) |
Ω(23 +1°C) |
10±1.5 |
Heater resistance (RH@ sensing temp.) |
Ω(400 +10°C) |
22±3 |
Heater resistance (RH@ reset temp.) |
Ω(525 +10°C) |
26±3 |
Heater power consumption (mW) typical for 5:1 |
VH= 2.7±0.2V (400°C) |
340±30 |
3.7±0.3V (525°C) |
530±50 |
|
Operating Temperature Range |
°C |
-20 to 120 |
|
|
|
P-type Metal Oxide VOC Sensor SENSITIVITY TO OTHER GASES |
||
EtOH sensitivity |
% measured gas @ 10 ppm EtOH |
TBA |
C3H8 sensitivity |
% measured gas @ 500 ppm C3H8 |
TBA |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Pre-calibrated module for combustible gas
-
Compact CO Sensor
-
15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
Carbon dioxide (CO2) sensor module
-
Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6
-
Thermal Conductivity Sensor for Leak or Pressure Detection
-
Ammonia Sensor (NH3 Sensor)