Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6 - KSIM 1260

  • Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6
Mouse over image to zoom

Measuring range​: 0…1000 ppm/0…5 Vol. % (others on request)​
Response time t90​: < 90 seconds​
Operating temperature​: -30 °C ... +70 °C​
Pressure range​: atmospheric ± 10%​
Air humidity​: 5...95%​
Protection class​: IP 54​
Supply voltage​: 16.0...30.0 VDC

  • Model Number: KSIM 1260
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6

 

KSIM 1260 Sulfur Hexafluoride SF6 Sensor Mode of operation
The KSIM 1260 is a high quality infra red Sulfur Hexafluoride gas detector designed to operate with KIMESSA or third party control panels.

 

The infra red sensor technology is diffusion based and Sulfur Hexafluoride specific, housed in a robust metallic enclosure and designed for one-person calibration.

 

The versatile KSIM 1260 outputs allow for user selection of 0-20mA, 4-20mA, 0-10Vdc and digital BUS. The BUS option is used in conjunction with the addressable KIMESSA CANline-32-channel gas monitor panel, incorporating data logging and multi-optional programming capability. The SF6-detector is available with a linearised measuring range from 0…1000 ppm (0.1 Vol. %) up to 0…5.0 Vol. % and its output signal is temperature compensated from -30℃to +70℃.

 

A novel feature on the KSIM 1260 facilitates direct measurement of the gas level via a 3.5mm jack connection, enhancing the overall flexibility of the SF 6 sensor.

 

The KSIM 1260 is also designed for use with a hand held optical calibration tool called the CRC–Calibration Remote Control, permitting calibration of remote SF 6 sensors.


KSIM 1260 Sulfur Hexafluoride SF6 Sensor Technical specifications

Measuring range
0…1000 ppm/0…5 Vol. % (others on request)
Response time t90
< 90 seconds
Operating temperature
-30 °C ... +70 °C
Start up after reconditioning
maximum 1 h
Pressure range
atmospheric ± 10%
Air humidity
5...95%
Location sensitivity
none
Life-span at 20 °C
depends on the application
Protection class
IP 54
Weight
550 gr
Current consumption
maximum 60 mA
Output signal analogue (selectable with jumper) 
4...20 mA/ 0...20mA/ 0...10 VDC/ 2...10 VDC 
Cable analogue
3-core cable, shielded, 3x1.00m
Output signal BUS (digital)
CAN-Bus
Cable BUS (digital)
4-core cable, shielded, 4x1.00m2
Supply voltage
16.0...30.0 VDC

KSIM 1260 Sulfur Hexafluoride SF6 Sensor Cross sensitivity to other gases

Test gas
concentration of the test gas
display on the SF6-Detector
Ammonia NH3
100 ppm
...
Chlorine Cl2
50 ppm
...
Carbon Dioxide CO2
5000 ppm
...
Carbon Monoxide CO
250 ppm
...
Propane C3H8
5000 ppm
...
Sulphur Dioxide SO2
100 ppm
...
Hydrogen Sulphide H2S
50 ppm
...
Nitrogen Dioxide NO2
20 ppm
...
Nitric Oxide NO
48 ppm
...
Hydrogen H2
90 ppm
...

If you cannot find what you want, you can entrust OFweek to source for you. Just click: