Miniature Infrared CO2 Sensor Module - S8 Residential
▪ Measurement range: 400 to 2000 ppm. Up to 10000ppm extended range
▪ Accuracy: ±70 ppm±3% of reading
▪ Operating temperature: 0 to 50°C
▪ Operating humidity: 0 to 85% RH non condensed
▪ Miniature size
▪ Individually calibrated
▪ Maintenance-free
▪ Long term stability
▪ Low power consumption
- Quantity:
- - +
Product Specification
S8 Residential Miniature Infrared CO2 Sensor Module Description
S8 is a miniature safety switch that can be used in control and alarm applications. The sensor can be integrated in a wide range of different alarm applications where you want to detect CO2, such as leakage detection.
S8 Residential Miniature Infrared CO2 Sensor Module Technical specification
Item |
S8 Residential Article no. 004-0-0013 |
Target gas |
CO2 |
Operating Principle |
Non-dispersive infrared (NDIR) |
Measurement range |
400 to 2000 ppm (Note 1). Up to 10000ppm extended range (Note 2) |
Measurement interval |
2 seconds |
Accuracy |
±70 ppm±3% of reading (Notes 3 and 4) |
Pressure dependence |
+ 1.6 % reading per kPa deviation from normal pressure |
Response time |
2 minutes by 90% |
Operating temperature |
0 to 50°C |
Operating humidity |
0 to 85% RH non condensed |
Storage temperature |
-40 to 70°C |
Dimensions (mm) |
33.5 x 20 x 8.5 mm (max dimensions) |
Weight |
< 8 grams |
Power supply |
4.5V to 5.25V unprotected against surges and reverse connection |
Power consumption |
300 mA peak, 30 mA average |
Life expectancy |
15+ years |
Compliance with |
Emission:EN 61000-6-3:2007, EN 61000-6-4:2007 Immunity:EN 61000-6-1:2007 RoHS directive 2011/65/EU |
Serial communication |
UART, Modbus protocol (Note 5). Direction control pin for direct connection to RS485 receiver integrated circuit. |
Alarm output, Open Collector |
1000/800 ppm Normal state is conducting max 100 mA. Transistor open at CO2 High, OR Power Low, OR at Sensor Failure |
PWM output, 1 kHz |
0 to 100% duty cycle for 0 to 2000 ppm 3.3V push-pull CMOS output, unprotected |
Maintenance |
Maintenance-free for normal indoor applications with SenseAir® |
Note 1: Sensor is designed to measure in the range 400 to 2000 ppm with specified in the table accuracy. Nevertheless exposure to concentrations below 400 ppm may result in incorrect operation of ABC algorithm and shall be avoided for model with ABC on.
Note 2: Sensor provides readings via UART in the extended range but the accuracy is degraded compared to specification in the table one.Note 3: In normal IAQ applications. Accuracy is defined after minimum 3 weeks of continuous operation with ABC on. However, some industrial applications do require maintenance. Please, contact SenseAir for further information!
Note 4: Accuracy is specified over operating temperature range. Specification is referenced to certified calibration
mixtures. Uncertainty of calibration gas mixtures (+-2% currently) is to be added to the specified accuracy for absolute measurements.
Note 5: See specification { Modbus on SenseAir_R_S8 rev_P11_1_00.doc preliminary specification}
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector