Miniature Infrared CO2 Sensor Module - S8-4B
- Measurement range: 400 to 32000ppm
- Accuracy: ±1000ppm at alarm points between 7000 and 9000 ppm
- Measurement interval: 30 seconds
- Operating temperature: -5 to 60 ºC
- Operating humidity range: 0 to 95% RH non condensed
- LNE approved
- Miniature size
- Low power consumption
- Individually calibrated
- Quantity:
- - +
Product Specification
S8-4B Miniature Infrared CO2 Sensor Module General Description
The S8-4B CO2 sensor module is designed to serve as a CO2 safety switch when built-in into kerosene heaters. The sensor utilizes reliable and highly accurate infrared gas sensing technology. The electronic circuitry is optimized for low power consumption. Because of low current consumption the sensor is suitable for battery applications and has an average current consumption of 2 mA.
S8 can be customized for a variety of alarm and control applications.
S8-4B Miniature Infrared CO2 Sensor Module Key technical specification
Item |
S8-4B Article no. 004-0-0061 |
Target gas |
CO2 |
Operating Principle |
Non-dispersive infrared (NDIR) |
Measurement range |
400 to 32000ppm (represented internally in digital format) |
Measurement interval |
30 seconds |
Accuracy |
±1000ppm at alarm points between 7000 and 9000 ppm (Note 1) |
Pressure dependence |
+ 1.6 % reading per kPa deviation from normal pressure |
Gas diffusion response time |
2 minutes by 90% |
Operating temperature |
-5 to 60 ºC |
Operating humidity range |
0 to 95% RH non condensed |
Storage temperature |
-40 to +70°C |
Storage Environment |
0-95% RH non condensed non corrosive gases, no contamination to kerosene |
Dimensions (mm) |
61 x 20 x 8.5 mm (max dimensions) |
Weight |
< 10 grams |
Power supply |
4.5 to 7.0 VDC unprotected against surges and reverse connection |
Power consumption |
250 mA peak, 2 mA average |
Life expectancy |
5+ years in normal indoor / office environments |
Compliance with |
Tested according Emission EN 61000-6-3:2007, EN 61000-6-4:2007 Immunity EN 61000-6-1:2007 RoHS directive 2011/65/EU |
Output Alarm, Open Drain |
Open drain FET; 7V/ 800mA, protected by a zener diode, normally open, 100kWpull-up resistor to power (+). 8000/6500 (Alarm/Release) Normal state is open. Transistor conducting at (CO2 > 8000ppm) OR (Unloaded Power voltage < 4.5V) OR (Loaded Power voltage < 4.0V) OR (Sensor Failure detected by self-diagnostics) |
Maintenance |
Forced calibration (assuming 400 ppm exposure). |
Self-diagnostics |
Full self-diagnostics at power up and continuously running self-diagnostics at every measurement. |
Note 1: Accuracy is specified over operating temperature range. Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (+-2% currently) is to be added to the specified accuracy for absolute measurements.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector