LuminOx Optical Oxygen Sensor Evaluation Interface Board - LOX-EVB
• Converts the LuminOx TTL level
• RS232 output into 3 standard industrial outputs
• Auto detects ppO2 or O2% variants of LuminOx Sensor
• Supply Voltage: 4.75-5.25 Vdc
• Supply Current: <50mA
• Output Types: RS232, RS485 and 0-5V
• Operating Temperature: 0°C to +50°C
- Quantity:
- - +
Product Specification
LOX-EVB LuminOx Optical Oxygen Sensor Evaluation Interface Board General Description
The LuminOx Sensor family is a range of factory calibrated oxygen sensors which measure ambient ppO2 levels using the principle of fluorescence quenching by oxygen.
The LuminOx Evaluation interface Board has been designed to allow customers to quickly and easily evaluate the sensor with the minimum of effort or design work
The LuminOx Evaluation Kit simultaneously provides three outputs:
• RS232 (serial interface voltage levels)
• RS485 (Modbus RTU) port allows multiple sensors to be addressed on a bus
• 0-5V Analogue output for basic measurements of oxygen only
LOX-EVB LuminOx Optical Oxygen Sensor Evaluation Interface Board Benefits
• Converts the LuminOx TTL level
• RS232 output into 3 standard industrial outputs
• Auto detects ppO2 or O2% variants of LuminOx Sensor.
LOX-EVB LuminOx Optical Oxygen Sensor Evaluation Interface Board Applications
• Oxygen Detection
• Portable Equipment
• Breathing Apparatus
• Inerting
• Medical
• Lab Equipment
• Agriculture
• Incubation
• Fire Prevention
• Flue Gas in Condensing Boilers
LOX-EVB LuminOx Evaluation Interface Board Electrical and Environmental Specification
Supply Voltage (Vs) |
4.75-5.25 Vdc |
Supply Current (Is) |
<50mA |
Output Types |
RS232, RS485 (Modbus RTU) and 0-5V |
Operating Temperature |
0°C to +50°C |
Storage Temperature |
0°C to +60°C |
LOX-EVB LuminOx Evaluation Interface Board Performance Specification
LuminOx Sensor Compatibilit |
0-25% (O2 % version) 0-300mbar (ppO2 version) |
Resolution |
0.01% / 0.1mbar (Digital Outputs) 0.01V (0-5V Analogue Output) |
LOX-EVB LuminOx Optical Oxygen Sensor Evaluation Interface Board MECHANICAL
Connection |
9 Screw terminals |
PCB Dimensions |
75x55mm max |
The LuminOx range has been designed as an alternative to electrochemical sensors but with the benefits of RoHS compliance, long life and complete environmental compensation built-in.
The sensor is available with and without a built-in barometric pressure sensor. LuminOx’s native measurement is partial oxygen p ressure (ppO2) in mbar. By incorporating a barometric pressure sensor, LuminOx is able to measure O2 vol. % in addition to ppO2
Unlike electrochemical sensors, LuminOx requires no additional signal conditioning circuitry and connects directly to the customers microcontroller via 3.3V-level RS232 link. This reduces costs and simplifies system design.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor)
-
Industrial Luminescence-based Trace Oxygen Sensor
-
LuminOx Sealed Optical Oxygen Sensor (O2 Sensor)
-
LuminOx Flow-through Optical Oxygen Sensor
-
Oxygen Optical Digital Sensor
-
Optical Dissolved Oxygen Sensor
-
Optical Dissolved Oxygen Probe
-
Oxygen Analyzer
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-