LuminOx Sealed Optical Oxygen Sensor (O2 Sensor) - LOX-02-S
• Supply voltage: 4.5 - 5.5V DC
• Supply current: <7.5mA (streaming one sample per second), <20mA Peak
• Output Type: 3.3V TTL level USART
• Operating Temperature: -30°C to +60°C
• Humidity: 0 - 99% Rh (non-condensing)
• Barometric pressure range 500 to 1200mbar
- Quantity:
- - +
Product Specification
LOX-02-S LuminOx Sealed Optical Oxygen Sensor General Description
The LuminOx Sealed Optical Oxygen Sensor Range Offers Users With Application Requirements To Only Measure Sample Gas At The Front Face Of The Sensor.
The LuminOx Sealed Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of luminescence quenching.
The LuminOx Sealed Optical Oxygen Sensor (LOX-02-S) is an extension to the standard range of LuminOx oxygen sensors. It is a similar diffusion type sensor like the original LOX-02 sensor. However, the LOX-02-S has a sealed base that is gas-tight, meaning only the face of the sensor with the protective membrane needs to be in the sample gas environment, externally leaving easy access to the pins of the sensor.
The patented technology allows SST to produce a range of sensors that provides low power operation, while offering a much longer lifetime than electrochemical and galvanic sensors.
The sensors each have an internal sensor for temperature and barometric pressure compensation, meaning the customer does not need to consider this in their design. It also communicates directly to the customers USART so no signal conditioning circuitry is required.
LuminOx is a completely solid state sensor and contains no lead or liquid electrolytes. It is therefore 100% RoHS compliant. It also has virtually no cross sensitivity, allowing it to be used in applications where other technologies are unreliable due to the particular mix of gases present.
The luminescence quenching principle measures the partial pressure of oxygen (ppO2). The internal barometric pressure sensor measurement along with the ppO2 measurement allows an oxygen concentration (O2%) value to be calculated. The USART output allows the sensor to communicate the values of O2%, ppO2, barometric pressure, internal temperature and a sensor status.
LOX-02-S LuminOx Sealed Optical Oxygen Sensor Features
• Luminescence-based optical technology, NOT electrochemical
• Contains no hazardous materials; RoHS & REACH compliant
• Connects directly to a microcontroller without any additional circuitry
• Factory calibrated
• High accuracy
• Maintenance free
LOX-02-S LuminOx Sealed Optical Oxygen Sensor Benefits
• Compact, diffusion-type housing with sealed base
• Low power, long life due to non-depleting sensing principle
• Low cost
LOX-02-S LuminOx Sealed Optical Oxygen Sensor Technical Specifications
Supply voltage (Vs) |
4.5-5.5V DC |
Supply current (ls) |
<7.5mA (streaming one sample per second), <20mA Peak |
Output Type |
3.3V TTL level USART |
Temperature |
|
Operating: |
-30°C to +60°C |
Storage: |
-30°C to +60°C |
Humidity |
0 - 99% Rh (non-condensing) |
Barometric pressure range |
500 - 1200mbar |
LOX-02-S LuminOx Sealed Optical Oxygen Sensor Output Values
Oxygen range |
0 - 25% O2 |
Oxygen pressure range |
0 - 300mbar ppO2 |
Response time |
T90 < 30s (typical) |
Accuracy |
|
ppO2 |
< 2% FS |
Temperature |
Indication only |
Pressure |
±5mbar |
O2 |
Determined by ppO2 & pressure accuracy |
Resolution |
|
ppO2 |
0.1mbar |
Temperature |
0.1°C |
Pressure |
1mbar |
O2 |
0.01% |
Lifetime |
> 5 years |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor)
-
LuminOx Optical Oxygen Sensor Evaluation Interface Board
-
Industrial Luminescence-based Trace Oxygen Sensor
-
LuminOx Flow-through Optical Oxygen Sensor
-
Oxygen Optical Digital Sensor
-
Optical Dissolved Oxygen Sensor
-
Optical Dissolved Oxygen Probe
-
Oxygen Analyzer
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor