Optical Dissolved Oxygen Sensor - RDO BLUE
• POND AQUACULTURE
• RECIRCULATING AQUACULTURE SYSTEMS
• OPEN PEN AQUACULTURE
• SURFACE WATER SPOT SAMPLING
• REMOTE MONITORING VIA TELEMETRY
- Quantity:
- - +
Product Specification
RDO® Blue Optical Dissolved Oxygen Sensor Description:
RDO Blue uses In-Situ’s patented Optical Rugged Dissolved Oxygen technology, an EPA-approved dissolved oxygen measurement method ideal for measuring DO and temperature in even the harshest environments. Suitable for handheld use or long-term deployment in fresh water or saltwater, this low-maintenance dissolved oxygen probe offers robust performance at a lower cost than other DO meters.
RDO Blue requires no calibration or conditioning prior to deployment and doesn’t use membranes. The replaceable RDO Smart Sensor Cap stores calibration coefficients for automatic, error-free setup. And a unique, three-layer system provides unmatched chemical and abrasion resistance.
Use included Modbus/RS485 communication protocol to easily integrate with PLC systems or telemetry with HydroVu data services for real-time feedback and process control.
RDO® Blue Optical Dissolved Oxygen Sensor Applications:
• POND AQUACULTURE
• RECIRCULATING AQUACULTURE SYSTEMS
• OPEN PEN AQUACULTURE
• SURFACE WATER SPOT SAMPLING
• REMOTE MONITORING VIA TELEMETRY
RDO® Blue Optical Dissolved Oxygen Sensor Technical parameters:
SENSOR RATINGS |
|
SENSOR TYPE |
Optical Dissolved Oxygen Sensor |
RANGE, DO |
0-60 mg/L; 0-600% Saturation |
ACCURACY, DO |
+/- 0.1 mg/L (0-20 mg/L) +/-2% (20-60 mg/L) |
RESOLUTION, DO |
0.01 mg/L |
RESPONSE TIME, CAP |
T63<5s, T90<45s, T95<60s (RDO-X cap) |
UNITS, DO |
mg/L, ppm, % saturation |
RANGE, TEMP. |
-5℃ to 50℃ (23°F to 122°F) |
ACCURACY, TEMP. |
+/- 0.1℃ |
RESOLUTION, TEMP. |
0.01℃ |
UNITS, TEMP. |
Celsius, Fahrenheit |
SALINITY COMP. |
Fixed or real-time capable |
BAROMETRIC COMP. |
Fixed or real-time capable |
METHODS |
EPA-approved In-Situ® RDO methods 1002-8-2009, 1003-8-2009, 1004-8-2009 Standard Methods 4500-O |
ENVIRONMENTAL RATINGS |
|
PRESSURE |
150 psi from 0° to 50℃ |
DEPTH |
100m (328ft) @ 25℃ |
OPERATING TEMP. (NON-FREEZING) |
-5.0℃ to + 50.0℃(23°F to 122°F) |
STORAGE TEMP. |
-40℃ to + 65℃(-40°F to 149°F) |
COMPLIANCE |
EMC 2014/30/EU IEC 61000-6-2:2005 EN 55011:2009 |
IP RATING |
IP-67 with sensor cap off; IP-68 with sensor cap installed |
CHEMICAL RATINGS |
|
INTERFERENCES |
Alcohols >5%; hydrogen peroxide > 3%; sodium hypochlorite (commercial bleach) > 3%; gaseous sulfur dioxide; gaseous chlorine. Do not use in organic solvents (e.g., acetone, chloroform, methylene chloride, etc.), which may swell the sensing element (foil matrix) and destroy it. |
GENERAL RATINGS |
|
DIMENSIONS |
L 22.06 cm (8.69 in) x D 2.95 cm (1.16 in) |
WEIGHT |
205 g (0.5 lb) (without cable) |
WETTED MATERIALS |
Ryton®(PPS), Cycoloy® (PC/ABS), PC/PMMA, TPU |
COMMUNICATION OUTPUT |
Modbus/RS485 |
READING RATE |
1 reading every 1 second |
POWER REQUIREMENTS |
8 to 36 VDC |
POWER CONSUMPTION |
Maximum (measurement): 50 mA at 12 VDC Idle (communication only): 2 mA at 12 VDC |
WARRANTY |
2 years from date of shipment |
NOTES: Ryton is a registered trademark of Solvay SA.; Cycoloy is a registered trademark of SABIC GLOBAL Technologies B.V.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
LuminOx Fluorescence Optical Oxygen Sensor (O2 Sensor)
-
LuminOx Optical Oxygen Sensor Evaluation Interface Board
-
Industrial Luminescence-based Trace Oxygen Sensor
-
LuminOx Sealed Optical Oxygen Sensor (O2 Sensor)
-
LuminOx Flow-through Optical Oxygen Sensor
-
Oxygen Optical Digital Sensor
-
Optical Dissolved Oxygen Probe
-
Oxygen Analyzer
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor
-
Medical Electrochemical Galvanic Fuel Cell Percent Oxygen Sensor