Hydrogen Sensor - 4H2-1000
Temperature Range:-20 oC to 50 oC
Operating Humidity:15 to 90%RH non-condensing
Pressure Range:90 to 110 kPa
Bias Potential:0 mV
- Quantity:
- - +
Product Specification
Performance Characteristics:
Part Number |
CLE-0613-400 |
Nominal Range |
0 to 1000 ppm |
Maximum Overload |
2000 ppm |
Sensitivity |
0.02±0.01µA/ppm |
Baseline(20 ℃) |
<±0.2 µA |
Baseline Drift(-20 to 50 ℃) |
0 to 10 ppm equivalent |
Resolution |
10 ppm |
Response Time(T90) |
≤70 seconds |
Linearity |
Linear |
Long Term Output Drift |
< 2% signal/month |
Operation Conditions:
Temperature Range |
-20 ℃ to 50 ℃ |
Operating Humidity |
15 to 90 %RH non-condensing |
Pressure Range |
90 to 110 kPa |
Bias Potential |
0 mV |
Storage Life |
6 months in sealed container |
Storage Temperature |
0 ℃ to 20 ℃ |
Expected Operating Life |
2 years in air |
Warranty |
12 months from date of despatch |
Physical Characteristics:
Weight |
5 g (approx) |
Orientation Sensitivity |
None |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Pre-calibrated module for combustible gas
-
Compact CO Sensor
-
15x15 Indoor Air Quality Sensor 100 ppm C Package 110-802
-
P-type Metal Oxide Carbon Monoxide (CO) Sensor
-
P-type Metal Oxide VOC Sensor
-
Carbon dioxide (CO2) sensor module
-
Gas sensor KSIM 1260 for detection of Sulfur Hexafluoride SF6
-
Thermal Conductivity Sensor for Leak or Pressure Detection