Hydrogen Chloride Sensor (HCL Sensor) - HCL-B1
• Range: 100ppm HCl limit of performance warranty
• Sensitivity: 150 to 250 nA/ppm in 25ppm HCl
• Response time t90: < 200 (s) from zero to 25ppm HCl
• Resolution: < 0.1 RMS noise (ppm equivalent)
• Temperature range: -30 to +50°C
• Pressure range: 80 to 120 kPa
• Humidity range: 15 to 90 % rh continuous
• Weight: < 13 g
- Quantity:
- - +
Product Specification
HCL-B1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.
HCL-B1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE
Sensitivity
nA/ppm in 25ppm HCl
150 to 250
Response time
t90 (s) from zero to 25ppm HCl
< 200
Zero current
ppm equivalent in zero air
0 to 3
Resolution
RMS noise (ppm equivalent)
< 0.1
Range
ppm HCl limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero, 40ppm HCl
0 to 6
Overgas limit
maximum ppm for stable response to gas pulse
200
HCL-B1 Hydrogen Chloride Sensor HCL Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/year in lab air, monthly test
nd
Operating life
months until 80% original signal (12 month warranted)
nd
HCL-B1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL
Sensitivity @ 0°C
% (output @ 0°C/output @ 20°C) @ 25ppm HCl
80 to 95
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 25ppm HCl
100 to 108
Zero @ -20°C
ppm equivalent change from 20°C
< +0 to -1.0
Zero @ 50°C
ppm equivalent change from 20°C
< +0.5 to +2.5
HCL-B1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY
H2S sensitivity
% measured gas @ ppm H2S
< 280
NO2 sensitivity
% measured gas @ ppm NO2
< -150
Cl2 sensitivity
% measured gas @ ppm Cl2
< -100
NO sensitivity
% measured gas @ ppm NO
< 2
SO2 sensitivity
% measured gas @ ppm SO2 (transient peak)
< 1
CO sensitivity
% measured gas @ ppm CO
< 0.1
H2 sensitivity
% measured gas @ ppm H2
< 0.1
C2H4 sensitivity
% measured gas @ ppm C2H4
< 0.1
NH3 sensitivity
% measured gas @ ppm NH3
< 0.1
CO2 sensitivity
% measured gas @ 5% CO2
< 0.1
HCL-B1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to +50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in original container)
6
Load resistor
Ω (recommended)
10 to 33
Bias voltage
mV
not required
Weight
g
< 13
Matched Transmitter board for HCL-B1 HCL Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)