CO2 Sensor Module - T6713

  • CO2 Sensor Module
  • CO2 Sensor Module
Mouse over image to zoom

▪A reliable sensor design based on 20 years of engineering and manufacturing expertise.
▪Flexible CO2 sensor platform designed to interact with other microprocessor devices.
▪Small compact design allowing simple
product integration.


  • Model Number: T6713
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

CO2 Sensor ModuleTelaire T6713 Series):



    Telaire T6713 Series is ideal for applications where Carbon Dioxide(CO2)levels need to be measured and controlled for indoor air quality and energy saving applications, such as demand control ventilation.

    All units are factory-calibrated to measure CO2 concentration levels up to 5000 ppm.

 

CO2 Sensor ModuleTelaire T6713 SeriesFeatures:

An affordable gas sensing solution for OEMs.

Eliminates the need for calibration in most applications with Telaire's patented ABC LogicTM software. Lifetime calibration warranty.

A reliable sensor design based on 20 years of engineering and manufacturing expertise.

Flexible CO2 sensor platform designed to interact with other microprocessor devices.

Small compact design allowing simpleproduct integration.

 

CO2 Sensor ModuleTelaire T6713 SeriesSpecifications

Method

Non Dispersive Infrared (NDIR), gold plated optics, diffusion sampling (with Telaire's Patented ABC Logic Self Calibrated Algorithm)

Measurement Range2

0 to 5000 ppm

Dimensions

1.18 in X 0.61 in X 0.34 in

(30 mm X 15.6 mm X 8.6 mm)

Accuracy1)(5

400-5000 ppm+/-30ppm±3% of reading

400-2000 ppm+/-25 ppm±3% of reading

Temperature Dependence

5 ppm peror 0.5% of the reading per, whichever is greater

Stability

< 2% of FS over life of sensor (15 years typical)

Pressure Dependence

0.13% of reading per mm Hg

Calibration Interval

Not required

Response Time

< 3 minutes for 90% step change typical

Signal Update

Every 5 seconds

Warm Up Time

< 2 minutes (operational)

10 minutes (maximum accuracy)

Operating Conditions

14°F to 140°F (-10to 60)

0 to 95% RH, non-condensing

Storage Conditions

-22°F to 158°F (-30to 70)

Output

Digital3

I2C slave up to 100kHz

UART@ 19200 Baud w/Modbus support

PWM Output Mode

Two options:

Cycle period 1002 ms(-1Hz)

40 us (25kHz)

Power Supply Requirements4

 4.5-5.5 VDC

 Peak200mA155mAtypical

Average 25mA20mAtypical

Interface Connections

Designed for six (6) pin male header with 0.1 in2.54 mmspacing.Header not included.

Notes

(1) Tolerance based on span gas of ±2%,whichadds to the uncertainty, tested at Standard Ambient Temperature and Pressure (SATP).

(2) Subjecting sensors to environments less than 400 ppm for more than 15 minutes may affect accuracy due to ABC Logic algorithm.

(3) Please call for detailed product specifications.

(4) Based on nominal 5VDC input voltage. For best performance, DC supply should be a regulated, low noise power source.

(5) The module may exhibit a toleranceaddition of ±6Oppm when first installed. This wil be corrected by the ABC Logic in first weeks of operation.



If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service