Carbon Monoxide Sensor CO Sensor 4-Electrode - CO-A4
• Range: 500ppm limit of performance warranty
• Sensitivity: 220 to 375nA/ppm in 2ppm CO
• Response time t90: < 20s from zero to 10ppm CO
• Temperature range :-30 to 50 ℃
• Pressure range : 80 to 120 kPa
• Humidity range :15 to 90 % rh continuous
• Storage period : 6 months @ 3 to 20 ℃ (stored in sealed pot)
• Load resistor :33 to 100 Ω (AFE circuit is recommended)
• Weight : < 6g
- Quantity:
- - +
Product Specification
CO-A4 Carbon Monoxide Sensor Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.
CO-A4 Carbon Monoxide Sensor sizes:
20mm diameter, the industry standard size for portable gas detectors
The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology.
CO-A4 Carbon Monoxide Sensor CO Sensor PERFORMANCE |
||
Sensitivity |
nA/ppm in 2ppm CO |
220 to 375 |
Response time |
t90 (s) from zero to 10ppm CO |
< 20 |
Zero current |
nA in zero air at 20°C |
-100 to +10 |
Noise* |
±2 standard deviations (ppb equivalent) |
20 |
Range |
ppm limit of performance warranty |
500 |
Linearity |
ppm CO error at full scale, linear at zero, 15ppm CO |
< ± 1 |
Overgas limit |
maximum ppm for stable response to gas pulse |
2000 |
* Tested with Alphasense AFE low noise circuit |
||
|
|
|
CO-A4 Carbon Monoxide Sensor CO Sensor LIFETIME |
||
Zero drift |
ppb equivalent change/year in lab air |
< ±100 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 10 |
Operating life |
months until 50% original signal (24 month warranted) |
> 36 |
|
|
|
CO-A4 Carbon Monoxide Sensor CO Sensor ENVIRONMENTAL |
||
Sensitivity @ -20°C |
(% output @ -20°C/output @ 20°C) @ 5ppm CO |
50 to 85 |
Sensitivity @ 50°C |
(% output @ 50°C/output @ 20°C) @ 5ppm CO |
110 to 125 |
Zero @ -20°C |
nA change from 20°C |
10 to 40 |
Zero @ 50°C |
nA change from 20°C |
-120 to -200 |
|
|
|
CO-A4 Carbon Monoxide Sensor CO Sensor CROSS SENSITIVITY |
||
Filter capacity |
ppm·hrs H2S |
250,000 |
H2S sensitivity |
% measured gas @ 5ppm H2S |
< 0.1 |
NO2 sensitivity |
% measured gas @ 5ppm NO2 |
< -2 |
Cl2 sensitivity |
% measured gas @ 5ppm Cl2 |
< 0.1 |
NO sensitivity |
% measured gas @ 5ppm NO |
< -2 |
SO2 sensitivity |
% measured gas @ 5ppm SO2 |
< 0.1 |
H2 sensitivity |
% measured gas @ 100ppm H2 at 20°C |
< 10 |
C2H4 sensitivity |
% measured gas @ 100ppm C2H4 |
< 0.5 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 0.1 |
|
|
|
CO-A4 Carbon Monoxide Sensor CO Sensor KEY SPECIFICATIONS |
||
Temperature range |
°C |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
% rh continuous |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (AFE circuit is recommended) |
33 to 100 |
Weight |
g |
< 6 |
Matched Transmitter board for CO-A4 CO Sensor
Analogue Front End (AFE) Alphasense A4 Air Quality Sensors
The family of Analogue Front End (AFE) circuits are designed for use with the A4 air quality sensors. Connect the AFE with A4 sensors to your multtiplexed ADC and you are recording air quality data immediately.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)