Carbon Monoxide + Hydrogen Sulfide Sensor (CO + H2S Sensor) - CO/H2S-D2
• Range: 1000 ppm CO limit of performance warranty
• Range: 100 ppm H2S limit of performance warranty
• Sensitivity: 27 to 55 nA/ppm in 400ppm CO
• Sensitivity: 90 to 160 nA/ppm in 20ppm H2S
• Response time t90: < 25 (s) from zero to 400ppm CO
• Response time t90: < 30 (s) from zero to 20ppm H2S @ 20℃
• Temperature range: -30 to 50℃
• Humidity range: 15 to 90 %rh continuous
- Quantity:
- - +
Product Specification
CO/H2S-D2 Miniature Size Carbon Monoxide + Hydrogen Sulfide Sensor Introduction
The world wide use of multigas, portable, personal safety monitors has grown since the 1970s to include an ever increasing number of industries. The one requirement in common to the majority of these instruments is the need to measure both Carbon Monoxide and Hydrogen Sulfide simultaneously.
Alphasense now offers a compact, dual gas sensor which allows designers to reduce significantly instrument size and cost. The D2 sensor provides a unique approach to the dual gas sensor in both its size and working electrode configuration. The use of a high capacity filter over the Carbon Monoxide working electrode eliminates Hydrogen Sulfide cross sensitivity to Carbon Monoxide.
Proven in the field over many years, these sensors perform well even under long term, challenging conditions.
D2 Specification Carbon Monoxide Channel
Carbon Monoxide Sensor PERFORMANCE |
||
Sensitivity |
nA/ppm in 400ppm CO |
27 to 55 |
Response time |
t90 (s) from zero to 400ppm CO |
< 25 |
Zero current |
ppm equivalent in zero air |
< ± 6 |
Resolution |
rms noise (ppm equivalent) |
1 |
Range |
ppm CO limit of performance warranty |
1000 |
Linearity |
ppm error at full scale, linear at zero and 400 ppm CO |
< 40 |
Overgas limit |
maximum CO for stable response to gas pulse |
5000 |
|
|
|
Carbon Monoxide Sensor LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
< 0.5 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 4 |
Operating life |
months until 80% original signal (24 month warranted) |
24 |
|
|
|
Carbon Monoxide Sensor ENVIRONMENTAL |
||
Sensitivity @ -20℃ |
% (output @ -20℃/output @ 20℃) @ 100ppm CO |
45 to 70 |
Sensitivity @ 50℃ |
% (output @ 50℃/output @ 20℃) @ 100ppm CO |
105 to 125 |
Zero @ -20℃ |
ppm equivalent change from 20℃ |
-1 to 1 |
Zero @ 50℃ |
ppm equivalent change from 20℃ |
-1 to 4 |
|
|
|
Carbon Monoxide Sensor CROSS SENSITIVITY |
|
|
Filter Capacity |
ppm-hours of Hydrogen Sulfide |
15,000 |
H2S sensitivity |
% measured gas @ 20ppm H2S |
< 8 |
NO2 sensitivity |
% measured gas @ 10ppm NO2 |
< 0.1 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< 0.1 |
NO sensitivity |
% measured gas @ 50ppm NO |
< 50 |
SO2 sensitivity |
% measured gas @ 20ppm SO |
< 0.1 |
H2 sensitivity |
% measured gas @ 400ppm H2 @ 20℃ |
< 55 |
C2H4 sensitivity |
% measured gas @ 400ppm C2H4 |
< 200 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
< 0.1 |
|
|
|
Carbon Monoxide Sensor KEY SPECIFICATIONS |
||
Temperature range |
℃ |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
%rh continuous (see note below) |
15 to 90 |
Storage period |
months @ 3 to 20℃ (stored in sealed pot) |
6 |
Load resistor |
Ω (recommended) |
10 to 47 |
Weight |
g |
< 2 |
D2 Specification Hydrogen Sulfide Channel
Hydrogen Sulfide Sensor PERFORMANCE |
||
Sensitivity |
nA/ppm in 20ppm H2S |
90 to 160 |
Response time |
t90 (s) from zero to 20ppm H2S @ 20℃ |
< 30 |
Zero current |
ppm equivalent in zero air |
< ± 1 |
Resolution |
rms noise (ppm equivalent) |
<0.25 |
Range |
ppm H2S limit of performance warranty |
100 |
Linearity |
ppm error at full scale, linear at zero and 20ppm H2S |
0 to -9 |
Overgas limit |
maximum ppm H2S for stable response to gas pulse |
400 |
|
|
|
Hydrogen Sulfide Sensor LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
< 0.1 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 2 |
Operating life |
months until 80% original signal (24 month warranted) |
24 |
|
|
|
Hydrogen Sulfide Sensor ENVIRONMENTAL |
||
Sensitivity @ -20℃ |
% (output @ -20℃/output @ 20℃) @ 20ppm H2S |
75 to 90 |
Sensitivity @ 50℃ |
% (output @ 50℃/output @ 20℃) @ 20ppm H2S |
103 to 112 |
Zero @ -20℃ |
ppm equivalent change from 20℃ |
-0.3 to 0.2 |
Zero @ 50℃ |
ppm equivalent change from 20℃ |
< ±1 |
|
|
|
Hydrogen Sulfide Sensor CROSS SENSITIVITY |
||
NO2 sensitivity |
% measured gas @ 10ppm NO2 |
< -10 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< -10 |
NO sensitivity |
% measured gas @ 50ppm NO |
< 10 |
SO2 sensitivity |
% measured gas @ 20ppm SO2 |
< 10 |
CO sensitivity |
% measured gas @400ppm CO |
< 2 |
H2 sensitivity |
% measured gas @400ppm H2 |
< 1 |
C2H4 sensitivity |
% measured gas @400ppm C2H4 |
<1 |
NH3 sensitivity |
% measured gas @ 20ppm NH3 |
0 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)