Ammonia Sensor (NH3 Sensor) - NH3-AF
• Range: 100 ppm NH3 limit of performance warranty
• Sensitivity: 20 to 40 nA/ppm in 50ppm NH3
• Response time: < 60 t90 (s) from zero to 50ppm NH3
• Resolution: < 0.7 RMS noise (ppm equivalent)
• Temperature range: -30 to 50 °C
• Pressure range: 80 to 120kPa
• Humidity range: 15 to 90 % rh continuous
• Weight: < 6g
- Quantity:
- - +
Product Specification
NH3-AF Ammonia Sensor (NH3 Sensor) Schematic Diagram
NH3-AF Ammonia Sensor (NH3 Sensor) PERFORMANCE |
||
Sensitivity |
nA/ppm in 50ppm NH3 |
20 to 40 |
Response time |
t90 (s) from zero to 50ppm NH3 (300 seconds) |
< 60 |
Zero current |
ppm equivalent in zero air |
< ± 7 |
Resolution |
RMS noise (ppm equivalent) |
< 0.7 |
Range |
ppm NH3 limit of performance warranty |
100 |
Linearity |
ppm error at full scale, linear at zero and 40ppm NH3 |
+5 to -5 |
Overgas limit |
maximum ppm for stable response to gas pulse |
200 |
|
|
|
NH3-AF Ammonia Sensor (NH3 Sensor) LIFETIME |
||
Zero drift |
ppm equivalent change/year in lab air |
< 2 |
Sensitivity drift |
% change/year in lab air, monthly test |
< 3 |
Operating life |
months until 80% original signal (12 month warranted) |
> 24 |
|
|
|
NH3-AF Ammonia Sensor (NH3 Sensor) ENVIRONMENTAL |
||
Sensitivity @ -20°C |
% (output @ -20°C/output @ 20°C) @ 50ppm |
100 to 110 |
Sensitivity @ 50°C |
% (output @ 50°C/output @ 20°C) @ 50ppm |
100 to 110 |
Zero @ -20°C |
ppm equivalent change from 20°C |
-10 to 0 |
Zero @ 50°C |
ppm equivalent change from 20°C |
5 to 20 |
|
|
|
NH3-AF Ammonia Sensor (NH3 Sensor) CROSS SENSITIVITY |
||
H2S sensitivity |
% measured gas @ 20ppm H2S |
< ±3 |
NO2 sensitivity |
% measured gas @ 20ppm NO2 |
< -60 |
Cl2 sensitivity |
% measured gas @ 10ppm Cl2 |
< -300 |
NO sensitivity |
% measured gas @ 50ppm NO |
< 20 |
SO2 sensitivity |
% measured gas @ 20ppm SO2 |
nd |
CO sensitivity |
% measured gas @ 400ppm CO |
< 25 |
H2 sensitivity |
% measured gas @ 400ppm H2 |
< 15 |
C2H4 sensitivity |
% measured gas @ 400ppm C2H4 |
< 2 |
CO2 sensitivity |
% measured gas @ 5% CO2 |
0 |
|
|
|
NH3-AF Ammonia Sensor (NH3 Sensor) KEY SPECIFICATIONS |
||
Bias voltage |
mV (Working Electrode potential is above ground) |
+200 |
Temperature range |
°C |
-30 to 50 |
Pressure range |
kPa |
80 to 120 |
Humidity range |
% rh continuous |
15 to 90 |
Storage period |
months @ 3 to 20°C (stored in sealed pot) |
6 |
Load resistor |
Ω (recommended) |
10 to 47 |
Weight |
g |
< 6 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Electrochemical carbon monoxide sensor CO
-
Carbon Monoxide Sensor (CO Sensor)
-
Hydrogen Cyanide Sensor (HCN Sensor)
-
Phosphine Sensor (PH3 Sensor)
-
Nitric Oxide Sensor (NO Sensor)
-
Nitrogen Dioxide Sensor (NO2 Sensor)
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector
-
Ethylene Oxide Sensor (ETO Sensor)
-
Individual Sensor Board (ISB) Alphasense B4 4-Electrode Gas Sensors
-
Hydrogen Chloride Sensor (HCL Sensor)