Ultrasonic Wind Speed Sensor - SONIC-ANEMO-DVC
Output rat: 2 Hz / 30 Hz measurement
Wind module sensitivity: 0.12 m/s
Wind module resolution: 0.05 m/s (16 bits)
Wind module dynamic: 0.12 to 40 m/s
Direction sensitivity: +/-1.5°
Direction resolution: 1° (9 bits)
Power supply: 2.7 V to 35 V DC
Electrical consumption: 2.6 mA Avg. @ 12 V
Op. temp. without icing: -15° C to +55° C
- Quantity:
- - +
Product Specification
SONIC-ANEMO-DVC Ultrasonic Wind Speed Sensor Description:
As Worldwide Premiere launch, a specific version of the CV7-V which connects directly to the wind sensor input on Davis instruments.This sensor will allow the replacement of mechanical anemometers / wind vanes with no need of anything else but power supply.
It’s an exclusive and useful product for both, professionals and well-informed amateurs.
SONIC-ANEMO-DVC Ultrasonic Wind Speed Sensor Specification:
Output data format |
WA: 25KΩ, 5V max; WS: Pulse open collector 10 mA max |
Information transmited |
Instant. W. Speed, Instant. W. Angle |
Output rate |
2 Hz / 30 Hz measurement |
Wind module sensitivity |
0.12 m/s |
Wind module resolution |
0.05 m/s (16 bits) |
Wind module dynamic |
0.12 to 40 m/s |
Direction sensitivity |
+/-1.5° |
Direction resolution |
1° (9 bits) |
Power supply |
2.7 V to 35 V DC |
Electrical consumption |
2.6 mA Avg. @ 12 V |
Op. temp. without icing |
-15° C to +55° C |
Cable |
5 m / UV proof |
Connection |
RJ11, 2 wires Power Supply |
Weight of the head |
|
Weight of unit assembly |
200 gr with mounting part |
Mounting |
Vertical, 300 aluminium arm, Ø 16 mm |
Options
These industrial option are "Din" boxes with:
• 1x connection for 24VDC/AC power supply
• 1x connection for CV7-V data
• 1x 12 V connection for CV7-V power supply
• Galvanic isolation betwen power supply and analog outputs
• Galvanic isolation betwen power supply and sensor's power supply
• The sensor input is optocoupled.
420 AC
This option features :
• 1 4-20 mA output loop current for wind speed ranging from 0.25 Kts to 80 Kts and CV7 measurement check.
• 1 4-20 mA output loop current for wind direction ranging from 0 to 359° and CV7 measurement check.
• 2 Dry contacts for wind speed alarm
ANA-AC
This option features 3 outputs 0-10V:
• 0-15m/s
• 0-30m/s or 0-40m/s selectable
• 0-359° wind direction.
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Wind Speed Sensor
-
Wind Speed Sensor Weather Monitoring
-
Vortex Pole Mount Anemometer with Dual Digital Display
-
Vortex II Series Heavy Duty Anemometer with Reed Switch
-
Vortex Wind Sensor Classic
-
Ultrasonic Wind Speed Sensor
-
Ultrasonic Wind Speed Sensor
-
Ultrasonic Wind Speed Sensor
-
Ultrasonic Wind Speed Sensor
-
Ultrasonic Wind Speed Sensor