Output rate: 4 Hz / 60 Hz measurement
Wind module sensitivity: 0.12 m/s
Wind module resolution: 0.05 m/s
Wind module dynamic: 0.12 to 40 m/s
Direction sensitivity: +/-1.5°
Direction resolution: 1°
Power supply: 8 V to 30 V DC
Electrical consumption: 9 mA
Op. temp. without icing: -15° C to +50° C

  • Model Number: CV7-E
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

CV7-E Ultrasonic Wind Speed Sensor Description

The CV7-E is easily integrated into measurement and monitoring systems. Detects gusts with great responsiveness and low latency. The CV7-E is powered by 8-30 VDC power supply and it outputs RS232 / RS422 / 5 V level signal / NMEA0183.

The CV7-E shows a data rate twice faster than the CV7 and CV7-V with a data output 4 per second.
The small size of this sensor makes it very discreet.
Like every LCJ Capteurs products, CV7-E is energy efficient.

CV7-E has proved its value with universities ‘laboratories, scientific and wind tunnels successful tests.

It can be used connected to a PC and to any system featuring a NMEA® input port.

CV7-E Ultrasonic Wind Speed SensoSpecification:

Output data format

NMEA0183, MWV, XDR

Information transmited

Instant. W. Speed, Instant. W. Angle, avaibility

Output rate

4 Hz / 60 Hz measurement

Wind module sensitivity

0.12 m/s

Wind module resolution

0.05 m/s

Wind module dynamic

0.12 to 40 m/s

Direction sensitivity

+/-1.5°

Direction resolution

Power supply

8 V to 30 V DC

Electrical consumption

9 mA

Op. temp. without icing

-15° C to +50° C

Cable

25 cm / 4x0.22 mm2, 20 g/m

Connection

4 wires

Weight of the head

100 gr

Weight of unit assembly

200 gr with mounting part

Mounting

Vertical, 300 carbon arm, Ø 16 mm


Options
These industrial option are "Din" boxes with:
• 1x connection for 24VDC/AC power supply
• 1x connection for CV7-V data
• 1x 12 V connection for CV7-V power supply
• Galvanic isolation betwen power supply and analog outputs
• Galvanic isolation betwen power supply and sensor's power supply
• The sensor input is optocoupled.

420 AC
This option features :
• 1 4-20 mA output loop current for wind speed ranging from 0.25 Kts to 80 Kts and CV7 measurement check.
• 1 4-20 mA output loop current for wind direction ranging from 0 to 359° and CV7 measurement check.
• 2 Dry contacts for wind speed alarm

ANA-AC
This option features 3 outputs 0-10V:
• 0-15m/s
• 0-30m/s or 0-40m/s selectable
• 0-359° wind direction.