Optical Dissolved Oxygen & Temperature Sensor - OPTOD
• Measurement ranges: 0.00 to 20.00 mg/L
• Resolution: 0,01
• Accuracy: +/- 0.1mg/L, +/- 0.1 ppm, +/- 1 %
• Response time: 90% of the value in less than 60 seconds
• Temperature compensation: Via CTN
• Operating temperature: -10°C to +60°C
• Signal interface: Modbus RS-485 (standard) and SDI-12 (option)
• Sensor power-supply: 5 to 12 volts
- Quantity:
- - +
Product Specification
OPTOD Optical Dissolved Oxygen & Temperature Sensor Optical technology:
The OPTOD sensor is based on luminescent optical technology and is approved by the ASTM International Standard Method D888-05.
Without calibration requirements, and thanks to an ultra low power technology, the OPTOD sensor is suitable for field work as well as long and short term monitoring.
With no oxygen consumption, this technology gives an accurate measure in all situations, even in very low oxygen concentrations.
Digital Technology:
The "smart" OPTOD sensor stores calibration and history data within the sensor. This allows you a "plug and play" system without re-calibration.
Digitally optimised measurement technology
• Optical luminescence technology requires minimal maintenance
• Digital sensor: Modbus RS-485
• No calibration required and therefore little to no drift occurs
• Robust and Watertight
OPTOD Optical Dissolved Oxygen & Temperature Sensor Applications
• Industrial effluent treatment
• Urban waste water treatment
• Surface water monitoring
• Drinking water
OPTOD Optical Dissolved Oxygen & Temperature Sensor Specifications
Measurement |
|
Measurement principle |
Optical measure by luminescence |
Measurement ranges |
0.00 to 20.00 mg/L |
Resolution |
0,01 |
Accuracy |
+/- 0.1mg/L, +/- 0.1 ppm, +/- 1 % |
Response time |
90% of the value in less than 60 seconds |
Flow |
No flow necessary |
Temperature compensation |
Via CTN |
Operating temperature |
-10°C to +60°C |
Signal interface |
Modbus RS-485 (standard) and SDI-12 (option) |
Maximum refreshing time |
< 1 second |
Sensor power-supply |
5 to 12 volts |
Consumption |
Standby 25 μA, Average RS485 (1 measure/ second) : 4.4 mAAverage SDI12 (1 |
Sensor |
|
Dimensions |
Diameter: 25 mm ; length: 146 mm |
Weight Weight |
450g (sensor + cable 3 metres) |
Material Stainless steel |
316L |
Maximum pressure |
5 bars |
Connection |
9 armoured connectors, polyurethane jacket, barewires or waterproof Fisher |
Degree of protection |
IB68 up to gland |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Laboratory Dissolved Oxygen Sensor
-
Submersible Galvanic Dissolved Oxygen Sensor
-
UVT-LED Sensor UV Transmittance Sensor
-
4-20mA Dissolved Oxygen Transmitters
-
Dissolved Oxygen Sensor for Oxygen Measurement
-
Memosens Oxygen Sensor
-
Dissolved Oxygen Sensor
-
Optical Oxygen Sensor
-
Integrated Blue-green Algae Sensor
-
Integrated Water and Oil Sensor