• Measurement Technique: UV absorption method
• Measurement Wavelength/Pathlength: 254nm/1cm
• Measurement Range: 10 -100% UV transmittance
• Accuracy: +/- 1.0% T (full scale)
• Resolution: 0.1% T
• Sample Flow Rate/Maxium Pressure: n/a, 150psig
• Temperature Range: 32-122 °F (0-50 °C)
• IP Ingress Rating: IP66 housing, IP68 measurement head
- Quantity:
- - +
Product Specification
UVT-LED Sensor UV Transmittance Sensor
Parts covered by this product instruction sheet include:
UVT-LED-PW, UVT-LED-H, UVT-LED-SW, and all accessories and mounting hardware
UV-T is a measure of the amount of UV energy remaining after passing through a material (e.g., water sample or quartz) over a specific distance. UV Absorbance is a measure of the amount of UV light that is absorbed by a substance (e.g., water, microbial DNA, lamp envelope, quartz sleeve) at a specific wave-length (e.g., 254 nm). UV-Transmittance is related to UV Absorbance by the following equation (for a 1- cm path length): % UVT = 100 x 10 -A.
UV-Transmittance is typically;
• measured at 254 nm, corresponding to the peak output of mercury-based UV lamps
• measured over a path length of 1-cm
• represented as a percentage
UV-T has a strong effect on the dose delivery of a UV treatment system. As UV-T decreases, the intensity throughout the reactor decreases, which reduces the dose the treatment system delivers. UV treatment systems are sized to deliver the required UV dose under specified UV-T conditions for the application. UV-T will typically vary over time due to changing concentrations of compounds, seasonal effects and changes in biological activity of microorganisms within the water source.
UV-T monitors are commonly used as an input to a dose control strategy of a UV treatment system, helping to reduce over or under dosing. They are also used to monitor water quality to help diagnose operational problems.
UVT-LED Sensor UV Transmittance Sensor Specifications
Measurement Technique |
UV absorption method (single beam technique), reagent-free |
Measurement Wavelength /Pathlength |
254nm/1cm |
Measurement Range |
10 -100% UV transmittance (UVT) |
Accuracy |
+/- 1.0% T (full scale) |
Resolution |
0.1% T |
Sample Flow Rate/ Maxium Pressure |
n/a, 150psig |
Display |
LCD with LED backlight |
Measuring Interval |
60 seconds (UVT-LED-PW & -SW only) |
Inspection Interval |
6 months(UVT-LED-PW & -SW only) |
User Maintenance |
1hr/month typical |
Power Supply |
20-28V DC, 5A, maximum 200Ohm load, customer supplied (UVT-LED-PW & -SW) 24V DC to charge battery (UVT-LED-H) |
Output |
0-100% UVT (UVT-LED-H-WD, UVT-LED-H-NA only) 4-20mA (UVT-LED-PW & -SW) |
Temperature Range |
32-122 °F (0-50 °C) |
Weight |
UVT-LED-H - 0.78lbs (353g), UVT-LED-PW - 1.58lbs (717g), UVT-LED-SW - 1.78lbs(807g) |
Dimensions |
7.60"H x 2.60" cap x 1.25" probe (19.1cm H x 6.4cm Dia) - UVT-LED-H & -PW only, 9.4"H x 3.00" cap x 1.25" probe (23.9cm H x 7.6cm Dia) |
IP Ingress Rating |
IP66 housing, IP68 measurement head |
Certifications |
CE |
Warranty |
2 Year Limited Warranty |
UVT-LED Sensor UV Transmittance Sensor Ordering Information
Part Number |
Description |
UVT-LED-PW |
In-line Mount Process UV Transmittance Monitor (with wiper/auto cal.), 10m (33 ft), cleaning swab |
UVT-LED-SW |
Submersion Mount Process UV Transmittance Monitor (with wiper/auto cal.), includes 10m(33ft) detachable cable, cleaning swab |
UVT-LED-H-WD |
Handheld, Off-Line Transmittance Monitor with power supply (outside of North America), case, cleaning swab x 1 |
UVT-LED-H-NA |
Handheld, Off-Line Transmittance Monitor with power supply (North America only), case, cleaning swab x 1 |
UVT0001 |
Carrying Case for UVT-LED-H (included with UVT-LED-H-WD and UVT-LED-H-NA kits) |
UVT0002 |
Power/Communication Cable for UVT-LED-PW, 10m (33 ft)- included with UVT-LED-PW |
UVT0003 |
Power/Communication Cable for UVT-LED-PW, 20m (66 ft) |
UVT0004 |
Power/Communication Cable for UVT-LED-PW, 30m (99 ft) |
UVT0005 |
Worldwide Power Supply |
UVT0006 |
North American Power Supply |
UVT-SW-001 |
Detachable Power/Communication Cable for UVT-LED-SW, 10m (33 ft)- included with UVT-LED-SW |
UVT-SW-002 |
Detachable Power/Communication Cable for UVT-LED-SW, 20m (66 ft) |
UVT-SW-003 |
Detachable Power/Communication Cable for UVT-LED-SW, 30m (99 ft) |
UVT0011 |
Cleaning Swabs (pack of 50) |
UVT0008 |
Installation Fitting, 2" NPT 316SS |
UVT0009 |
Installation Fitting, Stainless Steel Pipe (requires welding) |
UVT0015 |
Installation Kit, Sanitary Flow Cell (3") |
UVT0021 |
Installation Fitting for PVC Pipe (2" NPT) |
UVT0023 |
Installation Kit, PVC Flow Cell (2") with connections for barbed fitting with quick-disconnect |
UVT0024 |
Installation Kit, Stainless Steel Flow cell (2") with 1/4" barbed fittings |
UVT0025 |
1.5" Sanitary Flange Cap, Stainless Steel |
UVT-SW-004 |
UVT-LED-SW Installation Kit, retrofit to other supplier installation kits that accept 1.25" diameter pipe. |
UVT-SW-005 |
UVT-LED-SW Installation Kit, Complete |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Laboratory Dissolved Oxygen Sensor
-
Submersible Galvanic Dissolved Oxygen Sensor
-
4-20mA Dissolved Oxygen Transmitters
-
Dissolved Oxygen Sensor for Oxygen Measurement
-
Memosens Oxygen Sensor
-
Dissolved Oxygen Sensor
-
Optical Oxygen Sensor
-
Integrated Blue-green Algae Sensor
-
Integrated Water and Oil Sensor
-
Integrated PH / ORP Sensor