Miniature CO2 Sensor Modules - T6703

  • Miniature CO2 Sensor Modules
  • Miniature CO2 Sensor Modules
Mouse over image to zoom

▪ An affordable gas sensing solution for OEMs.
▪ Eliminates the need for calibration in most applications with Telaire’s patented ABC LogicTM software. Lifetime calibration warranty.
▪ A reliable sensor design based on 20 years of engineering and manufacturing expertise.
▪ Compact design for simple product integration.

  • Model Number: T6703
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Carbon Dioxide (CO2) Sensor Modules

    Telaire T6703 Series of CO2 Modules is ideal for applications where CO2 levels need to be measured to assess indoor air quality, such as residential applications. All units are factory-calibrated to measure CO2 concentration levels up to 5000 ppm.

 

T6703 Carbon Dioxide (CO2) Sensor Modules Applications:

Air Purifiers

Air Conditioning

Home monitoring

Desktop IAQ

Consumer products

 

T6703 Carbon Dioxide (CO2) Sensor Modules Features

An affordable gas sensing solution for OEMs.

Eliminates the need for calibration in most applications with Telaires patented ABC LogicTM software. Lifetime calibration warranty.

A reliable sensor design based on 20 years of engineering and manufacturing expertise.

Flexible CO2 sensor platform designed to interact with other microprocessor devices.

Compact design for simple product integration.

 

T6703 Carbon Dioxide (CO2) Sensor Modules Specifications

Method

Non Dispersive Infrared (NDIR), gold plated optics,diffusion sampling (with Telaires Patented ABC Logic Self Calibrated Algorithm)

Measurement Range

0 to 5000 ppm

Dimensions

1.18 in X 0.61 in X 0.34 in

(30 mm X 15.6 mm X 8.6 mm)

Accuracy

400-5000 ppm ± 75 ppm or 10% of reading, whichever is greater

Temperature Dependence

5 ppm peror 0.5% of the reading per, whichever is greater

Stability

< 2% of FS over life of sensor (15 years typical)

Pressure Dependence

0.13% of reading per mm Hg

Calibration Interval

Not required

Response Time

< 3 minutes for 90% step change typical

Signal Update

Every 5 seconds

Warm Up Time

< 2 minutes (operational)

10 minutes (maximum accuracy)

Operating Conditions

14°F to 140°F (-10to 60)

0 to 95% RH, non-condensing

Storage Conditions

-22°F to 158°F (-30to 70)


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service