Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor - CozIR-LP

  • Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor
  • Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor
  • Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor
  • Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor
Mouse over image to zoom

Ultra-low Power 3mW
Measurement ranges from 0 to 1%
Accuracy: ±50 ppm +/- 3% of reading​
Operating Pressure Range: 950 mbar to 1050 mbar​
3.3V supply
Peak current only 33mA
Commands set and electrical interface compatible with GSS COZIR sensor range

  • Model Number: CozIR-LP
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

COZIR-LP Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor Description

The CozIR®-LP is part of a new generation of ambient CO₂ sensors optimised for low-power applications. The CozIR®-LP uses NDIR solid-state LED optical technology to create a sensor
with a small footprint and ultra-low-power consumption.
This makes it ideal for a new generation of portable and battery powered a mbient measurement applications that require highly accurate CO₂ measurement capability.
The CozIR®-LP sensor is designed for measuring ambient levels of CO₂ from 0-1%.
The sensor also features a built-in auto-zero function that maintains CO₂ measurement accuracy over the lifetime of the product.

COZIR-LP Low Power Low Profile Carbon Dioxide Sensor NDIR CO2 Sensor Features


    •  Ultra-low power CO₂ sensor
    •  30ppm (typ.) measurement accuracy
    •  Solid-state LED optical technology
    •  UART data interface
    •  Built-in auto-zero function
    •  California Building Standards Code,Title 24 compliant


COZIR-LP Carbon Dioxide Sensor NDIR CO2 Sensor Specifications

General Performance
Start up time
First reading 1.2s after power on
Operating Conditions

0°C to 50°C (Standard)

-25°C to 55°C (Extended range)

0 to 95% RH, non-condensing

Recommended Storage
-30°C to +70°C
CO2 Measurement
Sensing Method

Non-dispersive infrared (NDIR) absorption

Patented Gold-plated optics

Proprietary GSS Solid-state source and detector

Sample Method
Diffusion
Measurement Range
0-2000ppm, 0-5000ppm, 0-1%
Accuracy
±50 ppm +/- 3% of reading
Calibration
Autocalibration
Non Linearit
< 1% of FS
Pressure Dependence
0.13% of reading per mm Hg in normal atmospheric conditions
Operating Pressure Range
950 mbar to 1050 mbar
Response Time

2- 3 mins (Configurable via filter type and application)

Reading refreshed twice per second.

Electrical/ Mechanical
Power Input

3.25 to 5.5V. (3.3V recommended). 

Peak Current 33mA.

Average Current <1mA.

Connector
6-way 1.27mm header
Power Consumption
3 mW
Weight
5g
Dimensions
31mm x 19.5mm x 8mm

If you cannot find what you want, you can entrust OFweek to source for you. Just click: