Loop-Powered, Isolated Toroidal Conductivity Transmitter - TCSMA
• Measuring Range: 0-100,000 uS
• Sensitivity: 0.1% of span
• Repeatability : 0.2% of span
• Power Requirement: 16-35 VDC (2-wire device)
• Response Time: 5 seconds to 90% full scale
• 4-20mA isolated output, loop-powered (16-35V DC)
• Operating Temperature: -20 to 60 deg C
• Operating Humidity: 0-95% R.H. non-condensing
- Quantity:
- - +
Product Specification
TCSMA - Loop-Powered, Isolated Toroidal Conductivity Transmitter
TCSMA Toroidal Conductivity Transmitter Features
• 4-20mA isolated output, loop-powered (16-35V DC)
• User-adjustable temperature compensation (0-4%/ deg C)
• Selectable measuring ranges
• Adjustable zero and span
• Direct/reverse operation
• Nema 4X enclosure with multiple mounting configurations
TCSMA Toroidal Conductivity Transmitter Description
The TCSMA model is designed for on-line monitoring of water treatment applications and aggressive process chemicals. This blind transmitter is ideally suited for applications where 4-20mA signals are required and reliable instrumentation is critical.
Key features include: selectable measuring ranges, adjustable temperature compensation (%/deg C), isolated output and reversible cell drive.
A Nema 4X (IP66) enclosure provides durability. A variety of mounting choices are available for Wall, Pipe or DIN Rail installation.
Pair the TCSMA with a TCS3020 toroidal sensor for trouble-free service. TCS3000 and TCS3020 sensors are offered in Noryl construction and can be mounted in a custom flow cell (FC95C) for in-line use.
TCSMA Toroidal Conductivity Transmitter Specifications-Transmitter
Measuring Range |
0-100,000 uS, - preset at factory as 4-20mA |
Span Range |
2000-2500uS / 2500-15,00uS / 15,000-100,000uS / 100,00-1,000,000uS |
Sensitivity |
0.1% of span |
Repeatability |
0.2% of span |
Non-Linearity |
1% of span for span > 3000uS/cm --- 2% of span for span <3000uS/cm |
Zero Drift |
<1% span per month, non-cumulative |
Operating Conditions |
-20 to 60 deg C, 0-95% R.H. non-condensing conditions |
Temperature Drift |
0.06% of range/deg C, span or zero |
Stability |
0.2% of range per 24 hours, non-cumulative |
Power Requirement |
16-35 VDC (2-wire device) |
Insertion |
Loss 16 V DC |
Output Isolation |
Inherently isolated by sensor design |
Enclosure |
NEMA 4X (IP66) polycarbonate, wall, pipe or DIN Rail mount. Weatherproof and corrosion resistant. Dimensions = 4.4" (112mm) H x 4.4" (112mm) W x 3.5" (89mm) D. |
Weight |
1lb (0.45Kg) |
Conduit Openings |
2 each PG-9. Cord grips included. |
Temperature Input |
Pt1000RTD. Compensation adjustable from 0.0%/deg C to 4.0%/deg C |
Maximum Cable Length |
200ft. (61.0m) |
Response Time |
5 seconds to 90% full scale |
TCSMA Toroidal Conductivity Transmitter Ordering Information
Part Number |
Description |
TCSMA |
Blind, Loop-powered, 4-20mA toroidal conductivity transmitter (16-35VDC power supply not included) |
TCS3020 |
Keyed Noryl toroidal conductivity sensor. Includes 20ft of cable and tinned wire terminations |
FC95C |
Keyed CPVC flow cell for TCS3020. Includes nut and o-ring seal. |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Smart Aqua Meter for pH, ORP or Conductivity and Temperature Meter
-
Menu Driven Loop-Powered Toroidal Conductivity Transmitter
-
Loop-Powered Contacting Conductivity Transmitter
-
Loop-Powered Dissolved Oxygen Transmitter
-
pH/mV Transmitter
-
All-in-one Solution for Optical Oxygen Measurement
-
Multi-parameter (COD / BOD / TOC) Water Quality Automatic Analyzer
-
Cabinet Mounted Turbidity / TSS / MLSS Analyzers
-
Cabinet Installed Chlorine Analyzer (Polarography)
-
On-line TRO Analyzer (DPD Spectrophotometry)