Loop-Powered Contacting Conductivity Transmitter - CX100

  • Loop-Powered Contacting Conductivity Transmitter
  • Loop-Powered Contacting Conductivity Transmitter
Mouse over image to zoom

• Accuracy: ±1% of full scale reading in respective range
• Temperature: 0 °C to 100 °C (32 °F to 212 °F)
• Temperature Resolution: 0.1 °C (0.1 °F)
• Relative Temperature Accuracy: ±0.5 °C (±0.9 °F)
• Sensor Pt100: (3 wire / 2 wire)
• Power Requirements: 12 to 24V DC, maximum 600 Ohm load
• Certifications: CE

  • Model Number: CX100
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

CX100 Loop-Powered Contacting Conductivity Transmitter
Item No.: CX100


CX100 
Loop-Powered Contacting Conductivity Transmitter Features

• Six selectable conductivity ranges for a wide range of measurements

• Isolated Output prevents output interference caused by electrical noise or leakage from the input source
• Out-of-range Output Current Indicator indicates an out-of-range measurement by emitting a 3.8mA output current
• Hold Output Current Indicator to indicate ‘HOLD’ mode during calibration or set up mode.
• Scaleable 4-20 mA Current Output
• Primary and secondary display for simultaneous display of Conductivity and Temperature values
• Easy Push Button Operation
• Automatic (with Pt 100) or manual Temperature Compensation
• Panel or Wall Mount, Nema 4x, IP65 Weatherproof Housing


CX100 Loop-Powered Contacting Conductivity Transmitter Description
This isolated output 4-20mA industrial transmitter, 
a sturdy microprocessor-based instrument, measures conductivity and temperature. It transmits conductivity measurements via a two-wire power supply loop. The industrial transmitter has many user friendly features - all of which are easily accessible via the water resistant membrane keypad. Ideal for connecting to a PLC for advanced control systems, the transmitter can also be connected to a recorder for a low-cost documentation system. The instrument housing is designed for panel or wall mounting.


CX100 Loop-Powered Contacting Conductivity Transmitter Specifications

Conductivity Ranges
 R1: 0-19.99 µS/cm, 0.01 µS/cm resolution
 R2: 0-199.9 µS/cm, 0.1 µS/cm resolution
 R3: 0-1999 µS/cm, 1µS/cm resolution
 R4: 0-10.00 mS/cm, 0.01 mS/cm resolution
 R5: 0-19.99 mS/cm, 0.01 mS/cm resolution
 R6: 0-199.9 mS/cm, 0.1 mS/cm, resolution
Cell Constants
 k=0.1, R1-R5
 k=1.0, R1-R6
 k= 10.0, R2-R6 
Accuracy
 ±1% of full scale reading in respective range
Temperature
 0 °C to 100 °C (32 °F to 212 °F)
Temperature Resolution
 0.1 °C (0.1 °F)
Relative Temperature Accuracy
 ±0.5 °C (±0.9 °F)
Sensor Pt100
 (3 wire / 2 wire)
Temperature Compensation
 Auto/Manual
Output
 4.0-20.0mA (Galvanically isolated)
Cell Constant User-Selectable
 (0.10 to 10.00)
Temperature Coefficient  0 to 10% (selectable)
Normalization Temperature
 20.0 °C to 25 °C
Display
 Dual Display Custom LCD
Power Requirements
 12 to 24V DC, maximum 600 Ohm load
Dimension
 96 x 96 x 66 mm (3.78 x 3.78 x 2.6 inch)
Weight
 210 g
Certifications
 CE



If you cannot find what you want, you can entrust OFweek to source for you. Just click: