Liquid Analytical Sensors - S80

  • Liquid Analytical Sensors
  • Liquid Analytical Sensors
Mouse over image to zoom

• Measure pH, ORP, Specific Ion, Dissolved Oxygen, Turbidity, Conductivity or Resistivity
• Multiple individual measurement parameters in the same mechanical configuration
• Long life replaceable electrode cartridges lower the over all operating cost
• Submersible and Retractable Sensors Various process fitings with adjustable insertion lengths
• Industrial housing materials for compatibility with process fluid

  • Model Number: S80
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

Measure pH, ORP, Specific Ion, Dissolved Oxygen, Turbidity, Conductivity or Resistivity with Model T80 Universal Transmitter


S80 Liquid Analytical Sensors Overview
The intelligent sensor choice to fit your application. The S80 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flaired end to prevent blow out. The standard Model S80 sensors have a rugged ¾" O.D. 316 stainless steel body with a 10 ft. cable or an optional waterproof detachable cable assembly.

Electro-Chemical Devices offers a complete line of liquid analytical sensors: pH, ORP, Specific Ion, Dissolved Oxygen, Conductivity & Resistivity. The technical advantage of the Model S80 Intelligent Sensors are the 6 points of design flexibility to configure a sensor that best fits your application.

S80 Liquid Analytical Sensors 6 Point Advantage
1. Intelligent sensor design with digital communication Calibration data is stored in the sensor allowing field installation of a pre-calibrated sensor. Detachable cable option simplifies the installation of pre-calibrated sensors.
2. Multiple individual measurement parameters in the same mechanical configuration- pH, ORP, Specific Ion, Dissolved Oxygen, Conductivity & Resistivity
3. Readily available application specific electrode cartridges. Many unique pH electrode design formulations and materials of construction which are
field proven and selected for long life and accuracy.
4. Long life replaceable electrode cartridges lower the over all operating cost. 
5. Submersible and Retractable Sensors Various process fitings with adjustable insertion lengths - threaded fitings, sanitary fitings, flanges and valve retractable fitings.
6. Industrial housing materials for compatibility with process fluid. Stainless Steel, Titanium, HastelloyC-22, Polypropylene or PVDF(Kynar TM ). Standard 10" or 17" lengths additional lengths available.

S80 Liquid Analytical Sensors Product Specifications
S8
All Sensors
Dimensions:
S80 Insertion - ¾”OD x 10” Length
S80 Valve Retractable - ¾” OD x 17”
Cable Length:
10 ft. standard, optional lengths in 10 ft increments, 
optional Detachable cable connection

Housing Materials:
  Standard:
316 Stainless Steel
  Optional:
Titanium (T), grade 2 Hastelloy C-22 (H), 
PVDF (K) Polypropylene (P)

O-Ring Materials:
  Standard:
Viton® (VIT)
  Optional:
Ethylene Propylene (EPR), VITON® 
75 (VIT75) Kalrez® (KLZ) CV75 (CV)

Process Connections:
  S80 Insertion/Immersion

  -75
¾" 316 SS gland fiting with nylon ferrule
  -75HT
¾" 316 SS gland fiting with Teflon® ferrule
 -75SF
¾" 316 SS gland fiting with stainless steel ferrule
  -75TFE
¾" Teflon® gland fiting with Teflon™ ferrule
  -100P
1" Polypropylene gland fiting for Polypropylene housing only
  S80 Valve Retractable

  -VSS
1" 316 SS valve retraction assembly
 -VSSE
1" 316 SS valve retraction assembly for Inductive sensors
  -VKY 1” PVDF valve retraction assembly
 -VPP
1" Polypropylene Valve Retraction assembly


PHS80 
pH measurement
Measurement Range:
0-14 pH
Temperature Range:
0°C - 90°C
Optional HT version:
0°C - 140°C
Pressure Range:
0 - 100 psig @ 90°C
Temperature Compensation:
Automatic 0°C - 100°C
Accuracy ± 0.2°C


MVS80 
ORP & Specific Ion
Measurement Range:

  ORP:
-2000 mV to 2000 mV
  pIon:
Sensor Specific, ppb, ppm&ppt
Temperature Range:
ORP - 0°C - 90°C, pIon Sensor Specific
Pressure Range:
0 - 100 psig @ 90°C
Temperature Compensation:
Automatic 0°C- 100°C
Accuracy ± 0.2°C


DOS80 
Dissolved Oxygen
Measurement Range:
0-20 ppm, 0-150% SAT
Temperature Range:
0°C- 90°C
Pressure Range:
0 - 65 psig @ 90°C
Temperature Compensation:
Automatic 0°C- 100°C
Accuracy ± 0.2°C


CS98/RS8
Conductivity/Resistivity
Measurement Ranges:

  Conductivity:
0.5μS to 50 mS
  Resistivity:
0 - 20 MΩ
Temperature Range:
-5°C to 100°C
Optional HT version:
-5°C to 150°C
Pressure Range:
CS/RS80 0 - 100 psig
Temperature Compensation:
Automatic 0°C- 100°C
Accuracy ± 0.2°C,100K thermistor


CS80 
Inductive Conductivity
Measurement Ranges:
50 mS to 1000 mS
Temperature Range:
-5°C to 100°C
Pressure Range:
0 - 100 psig
Temperature Compensation:
Automatic 0°C - 100°C
Accuracy ± 0.2°C, 100K thermistor
Body material:
KYNAR (PVDF)


CSX2 Series
High Temperature Conductivity
Measurement Ranges:
1.0μS to 50mS
Temperature Range:
0°C to 200°C
Pressure Range:
0 - 250 psig ( 400psig @100°C)
Temperature Compensation:
Automatic 0°C - 200°C
Accuracy ± 0.2°C, 10K ohm platinum RTD
Wetted Materials:
316 SS and PEEK
Shipping Weight:

  S80 (10")
  S80 (17")
  S80-VSS
2.5 lbs (1.2 kg)
2.75 lbs (1.25 kg)
5.8 lbs (2.65 kg)

If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service