Infrared Carbon Dioxide (CO2) Sensor Thermopile Detector - IRC-AT
• IAQ Range: 0 to 5000ppm
• Temperature Signal : Integral thermistor
• Response Time (t90): < 40 s @ 20°C ambient
• MTBF: > 5 years
• Operating Temperature Range: -20 to +50°C
• Storage Temperature Range: -40 to +75°C
• Humidity Range: 0 to 95% rh non-condensing
- Quantity:
- - +
Product Specification
IRC-AT Infrared Carbon Dioxide (CO2) Sensor Description
Alphasense CO2 and Methane infrared sensors are supplied in the industry standard miniature (20mm diameter) gas sensor housing.
Patented optics give the best signal to noise ratio of any 20mm diameter NDIR and universal linearisation constants allow easy implementation.
The on-board temperature sensor allows for software compensation, including ideal gas law correction.
CO2
The IRC-AT with dual channel thermopile detector. This CO2 sensor is designed for IAQ, safety, combustion and high CO2 process control applications.
Application notes explain linearisation, temperature compensation and circuitry.
The IRC-AT cover the entire concentration range of measurement, simply implement the appropriate linearisation constants in software for your required range:
IAQ |
0 to 5,000ppm CO2 |
Safety |
0 to 5% CO2 |
Combustion |
0 to 20% CO2 |
Process control |
0 to 100% CO2 |
IRC-AT Infrared Carbon Dioxide (CO2) Sensor PERFORMANCE |
|
Maximum Power Requirements | 5.0 VDC, 60 mA max. (50% duty cycle source drive) |
Minimum Operating Voltage | 2.0 VDC, 20 mA max. (50% duty cycle source drive) |
Source Drive Frequency | 3 Hz |
Active Output in N2 (peak-to-peak) | 4 to 7 mV @ 3 Hz, 50% duty cycle |
Reference Output in N2 (peak-to-peak) | 2 to 5 mV @ 3 Hz, 50% duty cycle |
Response Time (t90) | < 40 s @ 20°C ambient |
Warm-up Time | To final zero ± 100 ppm: < 30 s @ 20°C |
|
To specification: < 30 minutes @ 20°C |
|
|
IRC-AT Infrared Carbon Dioxide (CO2) Sensor LIFETIME |
|
MTBF |
> 5 years |
|
|
IRC-AT Infrared Carbon Dioxide (CO2) Sensor KEY SPECIFICATIONS |
|
Temperature Signal |
Integral thermistor (NTC, R 25 = 100KΩ B= 3940 K) |
Operating Temperature Range |
-20°C to +50°C (linear compensation from 0 to 40℃) |
Storage Temperature Range |
-40°C to +75°C |
Humidity Range |
0 to 95% rh non-condensing |
TYPE |
Range (Application) |
Accuracy (%FS,
using universal linearisation coefficients) |
Zero
Resolution (ppm) |
Full Scale
Resolution (ppm) |
Zero
Repeatability (ppm) |
Full Scale
Repeatability (ppm) |
Universal
lin. coeff. b |
Universal
lin. coeff. c |
Span
calibration conc. |
IAQ |
0 to 5000ppm (IAQ) |
1 | 10 | 50 |
± 20 |
± 50 |
0.000325 |
0.9363 |
4000 ppm |
Other |
0 to 5 % vol (Safety) |
1.5 |
10 |
100 |
± 20 |
± 500 |
0.5411 |
0.6716 |
4% |
0 to 20 % vol (Combustion) |
2.5 |
10 |
2000 |
± 20 |
± 2500 |
1.0459 |
0.2932 |
16% |
|
0 to 100 % vol (Process Control) |
tbc |
10 |
tbc |
± 20 |
tbc |
tbc |
tbc |
100% |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Ultra Low Power Digital Output NDIR CO2 Gas Sensor
-
Ultra Low Power Carbon Dioxide Sensor NDIR CO2 Sensor
-
Low Cost HVAC Carbon Dioxide Sensor NDIR CO2 Sensor
-
Probe Type NDIR CO2 Sensor
-
High Speed Carbon Dioxide Sensor NDIR CO2 Sensor 20Hz 0-100%
-
Infrared Gas Sensor for Oil Industry Methane Sensor
-
High Resolution Infrared Methane (CH4) Sensor
-
Voltage Output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Voltage output Infrared Carbon Dioxide (CO2) Gas Sensor
-
Infrared Carbon Dioxide (CO2) Sensor Pyroelectric Detector