Fiberoptic Electric Field Sensor (Reflective Version) - EOFS-xx2 Series

  • Fiberoptic Electric Field Sensor (Reflective Version)
  • Fiberoptic Electric Field Sensor (Reflective Version)
Mouse over image to zoom

• No metal parts
• Passive
• Miniature
• Optical fiber readout
• High shock/vibration resistance
• High sensitivity
• Wide bandwidth
• High damage threshold

  • Model Number: EOFS-xx2 Series
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

EOFS-xx2 Series Fiberoptic Electric Field Sensor Product Description
This Electric-field sensor, based on EO effect and coupled with a dual-fiber collimator, is probed by a laser through optic fiber and packaged only with dielectric components. It is ideally suitable  to  remotely  and  non-intrusively measure electric fields and microwave radiation up to Gigahertz range.

EOFS-xx2 Series Fiberoptic Electric Field Sensor Features
• No metal parts
• Passive
• Miniature
• Optical fiber readout
• High shock/vibration resistance
• High sensitivity
• Wide bandwidth
• High damage threshold

EOFS-xx2 Series Fiberoptic Electric Field Sensor Applications
• Test & evaluation of HPM, HRI and EMP systems, such as Active Denial Systems & PAA radars

EOFS-112 Series Fiberoptic Electric Field Sensor Performance Specifications of High Frequency

High Frequency Sensor
Min
Typical
Max
Unit
Frequency
DC

7.0
GHz
Sensitivity*

8
mV/m-Hz 1/2
Maximum detectable E-field

200

kV/m
Damage E-field


5 MV/m
Package Dimension**
6.0 x 6.0 x 30.0
mm
* Defined by measuring with a 1550nm laser at 20mW and 10 MHz.
** High frequency sensor

EOFS-122 Series Fiberoptic Electric Field Sensor Performance Specifications of Low Frequency
Low Frequency Sensor
Min
Typical
Max
Unit
Frequency
DC

400 MHz
Sensitivity*

0.8
mV/m-Hz 1/2
Maximum detectable E-field


1 kV/m
Damage E-field


5 MV/m
* Defined by measuring with a laser at 20mW and 10 MHz.

EOFS-xx2 Series Fiberoptic Electric Field Sensor Ordering Information
EOFS- 
2

1 1


Type Configurarion Package
Fiber Type
Fiber Length Connector

11=High Freq
12=Low Freq

2Reflective

1: Standsrd

0: special

Bare fber=1
900um loose
tube=3
Special=0

Panda PM=1
For input
Special=0

MM 62.5/125=1
For Output
Special=0

0.25m=1
0.5m=2
1.0m=3
Special=0

None=1
FC/PC=2
FC/APC=3
SC/PC=4
SC/APC=5
ST/PC=6
LC=7
Special=0


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service