EZO Dissolved Oxygen Circuit - EZO-DO
• Reads: Dissolved Oxygen
• Range: 0.01 - 100+ mg/L, 0.1 - 400+ % saturation
• Accuracy: +/- 0.05 mg/L
• Max rate: 1 reading per sec
• Calibration: 1 or 2 point
• Data protocol: UART & I2C
• Operating voltage: 3.3V - 5V
• Data format: ASCII
- Quantity:
- - +
Product Specification
EZO Dissolved Oxygen Circuit
EZO-DO EZO Dissolved Oxygen Circuit Description
EZO Dissolved Oxygen circuit is a very sensitive device. This sensitivity is what gives the Dissolved Oxygen circuit its accuracy. This also means that the Dissolved Oxygen circuit is capable of reading micro-voltages that are bleeding into the water from unnatural sources such as pumps, solenoid valves or other probes/sensors.
When electrical noise is interfering with the Dissolved Oxygen readings it is common to see rapidly fluctuating readings or readings that are consistently off. To verify that electrical noise is causing inaccurate readings, place the Dissolved Oxygen probe in a cup of water by itself. The readings should stabilize quickly, confirming that electrical noise was the issue
When reading Dissolved Oxygen and Conductivity together, it is strongly recommended that the EZO™ Dissolved Oxygen circuit is electrically isolated from the EZO™ Conductivity circuit.
EZO-DO EZO Dissolved Oxygen Circuit Dimensions
EZO-DO EZO Dissolved Oxygen Circuit Power consumption
|
LED |
MAX |
STANDBY |
SLEEP |
5V |
ON |
13.5 mA |
13.1 mA |
0.66 mA |
OFF |
12.7 mA |
12.7 mA |
|
|
3.3V |
ON |
12.1 mA |
12 mA |
0.3 mA |
OFF |
11.9 mA |
11.9 mA |
|
EZO-DO EZO Dissolved Oxygen Circuit Absolute max ratings
Parameter |
MIN |
YP |
MAX |
Storage temperature
(EZO™ D.O.) |
-65 °C |
|
125 °C |
Operational temperature
(EZO™ D.O.) |
-40 °C |
25 °C |
85 °C |
VCC |
3.3V |
5V |
5.5V |
EZO-DO EZO Dissolved Oxygen Circuit Specifications
Reads |
Dissolved Oxygen |
Range |
0.01 - 100+ mg/L 0.1 - 400+ % saturation |
Accuracy |
+/- 0.05 mg/L |
Max rate |
1 reading per sec |
Supported probes |
Any galvanic probe |
Calibration |
1 or 2 point |
Temp. compensation |
Yes |
Salinity compensation |
Yes |
Pressure compensation |
Yes |
Data protocol |
UART & I2C |
Default I2C address |
97 (0x61) |
Operating voltage |
3.3V - 5V |
Data format |
ASCII |
Circuit dimensions |
13.97mm x 20.16mm (0.55" x 0.79") |
Weight |
1.77 grams |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing ServiceRecommended Products
-
Laboratory Dissolved Oxygen Sensor
-
Submersible Galvanic Dissolved Oxygen Sensor
-
UVT-LED Sensor UV Transmittance Sensor
-
4-20mA Dissolved Oxygen Transmitters
-
Dissolved Oxygen Sensor for Oxygen Measurement
-
Memosens Oxygen Sensor
-
Dissolved Oxygen Sensor
-
Optical Oxygen Sensor
-
Integrated Blue-green Algae Sensor
-
Integrated Water and Oil Sensor