Bending Beam and Shear Load Cells - FTK
• Special steel
Nominal load (E max): 75 -150 - 300 - 500 kg, 1000 - 2000 - 3000 - 5000 kg
• Combined error ≤ ±0.02%
• Protection class IP67, IP68
- Quantity:
- - +
Product Specification
FTK
Bending Beam and Shear Load Cells
• Special steel
• Combined error ≤ ±0.02%
• Protection class IP67, IP68
FTK Bending Beam and Shear Load Cells TECHNICAL FEATURES
Material |
Special steel |
|
OIML R60 Accuracy class • Verification intervals |
- |
C3 • 3000 |
Nominal load (E max) |
75 -150 - 300 - 500 kg |
1000 - 2000 - 3000 - 5000 kg |
Minimum verification interval (V min) |
- |
E max / 12000 |
Combined error |
≤±0.02% |
|
Protection class |
IP67 - IP68 |
Rated output |
2 mV/V ±0.1% |
Input resistance |
400 Ω ±10 |
Temperature effect on zero |
0.002% °C |
Output resistance |
352 Ω ±2 |
Temperature effect on span |
0.0012% °C |
Zero balance |
±2% |
Compensated temperature range |
-10 °C / +40 °C |
Insulation resistance |
≥5000 MΩ |
Operating temperature range |
-20 °C / +70 °C |
Safe overload (% of full scale) |
150% |
Creep at nominal load in 30 minutes |
0.03% |
Ultimate overload (% of full scale) |
250% |
Max supply voltage without damage |
15 V |
Deflection at nominal load |
0.6 mm |
FTK Bending Beam and Shear Load Cells ELECTRICAL CONNECTIONS
Cable lenght |
6 m |
Cable diameter |
5 mm |
Cores |
4/6 x 0.24 mm2 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service