100kg to 200t Load Cell - C2S
100kg to 200t Load Cell C2S
Class (OIML R60): C1, C2, C3
Combined Error: 0.045%, 0.023%, 0.018%
Material: Stainless Steel
Output: 2mV/V
Protectio
≤ ±0.024%
≤ ±0.017%n: IP68
- Quantity:
- - +
Product Specification
C2S
100kg to 200t Load Cell
Dimensions [mm]
Technical Data
ACCURACY CLASS: OIML R60 |
C1 |
C2 | C3 | |
LEGAL DIVISIONS |
1000 | 2000 | 3000 | |
NOMINAL LOAD (Emax) |
100-250-500 kg
1-2.5-5-7.5-10-20-30-50-75-100-150♢ -200♢ t
|
|||
MINIMUM VERIFICATION INTERVAL (Vmin) |
Emax / 10000 |
|||
COMBINED ERROR NON REPEATABILITY ZERO RETURN over 30 min. CREEP at nominal load: a) over 30 min. b) over 20 and 30 min. |
≤ ±0.045%
≤ ±0.015% ≤ ±0.036% ≤ ±0.035% ≤ ±0.010% |
≤ ±0.023%
≤ ±0.010% ≤ ±0.026% ≤ ±0.028% ≤ ±0.008% |
≤ ±0.018% ≤ ±0.008% ≤ ±0.016% ≤ ±0.022% ≤ ±0.005% |
|
TEMPERATURE EFFECT (10 °C) a) on zero b) on sensitivity |
≤ ±0.030% |
|
|
|
NOMINAL SENSITIVITY CALIBRATION TOLERANCE |
2mV/V
≤ ±0.1%
|
|||
INPUT RESISTANCE OUTPUT RESISTANCE INSULATION RESISTANCE ZERO BALANCE RECOMMENDED SUPPLY VOLTAGE NOMINAL SUPPLY VOLTAGE MAXIMUM SUPPLY VOLTAGE |
700 ± 2 Ω 700 ± 2 Ω > 5 GΩ ≤ ± 1% 10 V 1-15 V 18 V |
|||
MECHANICAL LIMIT values referred to nominal load: a) minimum load b) service load c) max permissible load d) breaking load e) max transverse load f) max permissible dynamic load |
0% |
|||
NOMINAL LOAD DISPLACEMENT AT NOMINAL LOAD |
100kg…10t ~0.06 mm |
20t - 30t ~0.16 mm |
50t…100t ~0.23 mm |
150t - 200t ~0.36 mm |
REFERENCE TEMPERATURE TEMPERATURE NOMINAL RANGE SERVICE TEMPERATURE STORAGE TEMPERATURE |
+23°C -10/+40 °C -20/+70 °C -20/+80 °C |
|||
WEIGHT
PROTECTION CLASS (EN 60529)
FIXING SCREWS |
~1.3 kg |
~3.4 kg |
~9.4 kg |
~18.2 kg |
IP68 (100h at 1m water column)
Acciaio Inox / Stainless Steel
5m
|
||||
|
|
|
|
♢ C3 class not available for 150t and 200t.
If you cannot find what you want, you can entrust OFweek to source for you. Just click: