1kg to 50kg Load Cell - TCA

  • 1kg to 50kg Load Cell
  • 1kg to 50kg Load Cell
  • 1kg to 50kg Load Cell
Mouse over image to zoom

1kg to 50kg Load Cell TCA
Nominal Load from 1kg to 50kg
Linearity: 0.03%
Output: 2mV/V
Protection: IP67

  • Model Number: TCA
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

TCA

1kg to 50kg Load Cell


ALUMINIUM strain gages Load cell for the measurement of static and dynamic loads in COMPRESSION and TENSION


Dimensions   [mm]


Technical Data

NOMINAL LOAD
1(1) - 2(1) - 5(1) kg(2)
10 - 25 - 50 kg(2)
NOMINAL SENSITIVITY
SENSITIVITY TOLERANCE
2 mV/V
≤ ± 0.1%
TEMPERATURE EFFECT (10 °C)
a) on zero
b) on sensitivity

≤ ± 0.025 %
≤ ± 0.021 %

LINEARITY
HYSTERESIS
REPEATABILITY
≤ ± 0.03 %
≤ ± 0.03 %
≤ ± 0.01 %
INPUT RESISTANCE
OUTPUT RESISTANCE
INSULATION RESISTANCE
ZERO BALANCE
RECOMMENDED SUPPLY VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM SUPPLY VOLTAGE
440 ± 20 Ω
350 ± 2 Ω
>5 GΩ
≤ ± 1 %
10 V
1-15 V
18 V
MECHANICAL LIMIT VALUES
REFERRED TO NOMINAL LOAD:
a) service load
b) max permissible load
c) breaking load
d) max transverse load
e) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD

120 %

150 %
>300 %
50 %
50 %
∼ 0.3 mm

REFERENCE TEMPERATURE
TEMPERATURE NOMINAL RANGE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
+23 °C
-10 / +40 °C
-20 / +70 °C
-20 / +80 °C
WEIGHT
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL
CABLE LENGTH
∼ 0.3 kg
IP20
Alluminio / Aluminium
3 m
RECOMMENDED KNUCKLE JOINTS
DURBAL EM6
  (1) Supplied with overload protection TENSION and COMPRESSION (Max. 500% F.S.).
  (2) N calibrations on request


If you cannot find what you want, you can entrust OFweek to source for you. Just click:

Sourcing Service