5kg to 100kg Load Cell - FT6
5kg to 100kg Load Cell FT6
Nominal Load from 5 kg to 100 kg
Class (OIML R60): C2
Combined Error: 0.028%
Material: Stainless Steel
Output: 2mV/V
IP67
- Quantity:
- - +
Product Specification
FT6
5kg to 100kg Load Cell
Dimensions [mm]
Technical Data
ACCURACY CLASS: OIML 60 |
C2 |
LEGAL DIVISIONS |
2000 |
NOMINAL LOAD (Emax) |
5-10-20-30-50-100 kg |
MINIMUM VERIFICATION INTERVAL (Vmin) |
Emax / 10000 |
COMBINED ERROR NON REPEATABILITY ZERO RETURN over 30 min. CREEP to nominal load: a) over 30 min. b) over 20 and 30 min. |
≤ ±0.028% ≤ ±0.018% ≤ ±0.030%
≤ ±0.009% |
TEMPERATURE EFFECT (10 °C) a) on zero b) on sensitivity |
≤ ±0.025% |
NOMINAL SENSITIVITY SENSIVITY TOLERANCE |
2mV/V ≤ ±0.1% |
INPUT RESISTANCE OUTPUT RESISTANCE INSULATION RESISTANCE ZERO BALANCE RECOMMENDED SUPPLY VOLTAGE NOMINAL SUPPLY VOLTAGE MAXIMUM SUPPLY VOLTAGE |
420 ± 20Ω 350 ± 2Ω >5 GΩ ≤ ±1% 10 V 1-15 V 18 V |
MECHANICAL LIMIT values referred to nominal load: a) minimum load b) service load c) max permissible load d) breaking load e) max transverse load f) max permissible dynamic load DISPLACEMENT AT NOMINAL LOAD |
0% |
REFERENCE TEMPERATURE TEMPERATURE NOMINAL RANGE SERVICE TEMPERATURE STORAGE TEMPERATURE |
+23°C -10/+40 °C -20/+70 °C -20/+80 °C |
WEIGHT PROTECTION CLASS (EN 60529) EXECUTION MATERIAL CABLE LENGTH |
~ 1.0 kg IP67 Acciaio Inox / Stainless Steel 5m |
FIXING SCREWS a) diameter b) resistance class c) tightening torque |
M6 |
If you cannot find what you want, you can entrust OFweek to source for you. Just click:
Sourcing Service