350kg to 7.5t Load Cell - FT1 - FT1A

  • 350kg to 7.5t Load Cell
Mouse over image to zoom

350kg to 7.5t Load Cell FT1 - FT1A
Nominal Load from 350kg to 7.5t
Class (OIML R60): C2, C3
Combined Error: 0.020%
Material: Stainless Steel
Output: 2mV/V
Protection: IP68

  • Model Number: FT1 - FT1A
  • Data Sheet: Date Sheet File
Quantity:
- +

Product Specification

FT1 - FT1A

350kg to 7.5t Load Cell


Dimensions   [mm]


Technical Data

ACCURACY CLASS: OIML R60
C2
C3
LEGAL DIVISIONS
2000
3000
NOMINAL LOAD (Emax)
350-500 kg
1-2-3-5-7.5t
MINIMUM VERIFICATION INTERVAL (Vmin)
E max / 1000 (FT1A: E max / 1500)
COMBINED ERROR
NON REPEATABILITY
ZERO RETURN over 30 min.
CREEP at nominal load:
a) over 30 min.
b) over 20 and 30 min.
≤ ±0.024%
≤ ±0.012%

≤ ±0.028%


≤ ±0.026%
≤ ±0.012%
≤ ±0.020%
≤ ±0.010%

≤ ±0.020%


≤ ±0.010%
≤ ±0.008%
TEMPERATURE EFFECT (10 °C)
a) on zero
b) on sensitivity


≤ ±0.026%
≤ ±0.020%


≤ ±0.014%
≤ ±0.014%

NOMINAL SENSITIVITY
SENSIVITY TOLERANCE
2mV/V
≤ ±0.1%
INPUT RESISTANCE
OUTPUT RESISTANCE
INSULATION RESISTANCE
ZERO BALANCE
RECOMMENDED SUPPLY VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM SUPPLY VOLTAGE
420 ± 20Ω
350 ± 2Ω
> 5 GΩ
≤ ±1% (FT1A: ≤ ±0.5%)
10 V
1-15 V
18 V
MECHANICAL LIMIT values referred to
nominal load:
a) minimum load
b) service load
c) max permissible load
d) breaking load
e) max transverse load
f) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD



0%
120%
150%
>300%
50%
50%
from ~0.2 to ~0.5 mm

REFERENCE TEMPERATURE
TEMPERATURE NOMINAL RANGE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
+23C
-10/+40 °C
-20/+70 °C
-20/+80 °C
WEIGHT
~ 1.1 kg
~ 2.6 kg
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL
CABLE LENGTH
IP68 (100h at 1m water column)
Acciaio Inox / Stainless Steel
5m
FIXING SCREWS
a) diameter
b) resistance class
c) tightening torque


M12
12.9
150 Nm


M20
12.9
160 Nm

If you cannot find what you want, you can entrust OFweek to source for you. Just click: