20t to 100t Load Cell - D200
20t to 100t Load Cell D200
Nominal Load from 20t to 100 t
Linarity: 0.10%
Material: Stainless Steel
Output: 2mV/V
LASER welded
- Quantity:
- - +
Product Specification
D200
20t to 100t Load Cell
Dimensions
Technical Data
ACCURACY CLASS: |
0.1% |
|
LINEARITY and HYSTERESIS |
0.1% |
|
NOMINAL LOAD |
20 t – 30 t |
50 t - 75 t - 100 t |
TEMPERATURE EFFECT (10 °C) a) on zero b) on sensitivity |
≤ ±0.028%
≤ ±0.008%
|
|
NOMINAL SENSITIVITY CALIBRATION TOLERANCE |
2 mV/V
≤ ±0.1%
|
|
INPUT RESISTANCE OUTPUT RESISTANCE INSULATION RESISTANCE ZERO BALANCE RECOMMENDED SUPPLY VOLTAGE NOMINAL SUPPLY VOLTAGE MAXIMUM SUPPLY VOLTAGE |
420 ± 20Ω
350 ± 2Ω
> 5 GΩ
≤ ±1%
10 V
1÷15 V
18 V
|
|
MECHANICAL LIMIT values referred to nominal load: a) minimum load b) service load c) max permissible load d) breaking load e) max transverse load REFERENCE TEMPERATURE TEMPERATURE NOMINAL RANGE WORKING TEMPERATURE STORAGE TEMPERATURE |
0%
120%
150%
> 200%
50%
+23°C
-10/+40 °C
-20/+70 °C
-20/+80 °C
|
|
WEIGHT PROTECTION CLASS (EN 60529) EXECUTION MATERIAL |
~ 10 kg |
∼ 19 kg |
IP65 ◊
Acciaio Inox / Stainless Steel
|
||
CONNECTION |
Connettore MIL-C-5015 7 poli maschio
MIL-C-5015 7 poles male connector
|
If you cannot find what you want, you can entrust OFweek to source for you. Just click: