• 500kg to 10t Load Cell
Mouse over image to zoom

500kg to 10t Load Cell

ISweek online 2h ago

ISweek_com

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    FT2
  • Data Sheet

  • Package

    Original packaging
  • Specs

    FT2
  • Quantity

    - +
  • Send Inquiry

Product Description

FT2

500kg to 10t Load Cell


Dimensions


Technical Data

ACCURACY CLASS: OIML R60
C2
C3
LEGAL DIVISIONS
2000
3000
NOMINAL LOAD (Emax)
500 kg
1-2-5-10 t
MINIMUM VERIFICATION INTERVAL (Vmin)
E max / 10000
COMBINED ERROR
NON REPEATABILITY
ZERO RETURN over 30 min.
CREEP to nominal load:
a) over 30 min.
b) over 20 and 30 min.
≤ ±0.022%
≤ ±0.015%

≤ ±0.026%


≤ ±0.028%
≤ ±0.010%
≤ ±0.019%
≤ ±0.010%

≤ ±0.018%


≤ ±0.012%
≤ ±0.009%
TEMPERATURE EFFECT (10 °C)
a) on zero
b) on sensitivity


≤ ±0.025%
≤ ±0.009%

±0.016%
≤ ±0.006%

NOMINAL SENSITIVITY
SENSIVITY TOLERANCE
2mV/V
≤ ±0.1%
INPUT RESISTANCE
OUTPUT RESISTANCE
INSULATION RESISTANCE
ZERO BALANCE
RECOMMENDED SUPPLY VOLTAGE
NOMINAL SUPPLY VOLTAGE
MAXIMUM SUPPLY VOLTAGE
420 ± 20Ω
350 ± 2Ω
>5 GΩ
≤ ±1%
10 V
1-15 V
18 V
MECHANICAL LIMIT values referred to
nominal load:
a) minimum load
b) service load
c) max permissible load
d) breaking load
e) max transverse load
f) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD



0%
120%
150%
>300%
50%
50%
~ 0.5 mm

REFERENCE TEMPERATURE
TEMPERATURE NOMINAL RANGE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
+23°C
-10/+40 °C
-20/+70 °C
-20/+80 °C
WEIGHT
~ 2.3 kg
~ 4.3 kg
~ 8.0 kg
PROTECTION CLASS (EN 60529)
EXECUTION MATERIAL
CABLE LENGTH
IP68 (100h at 1m water column)
Acciaio Inox / Stainless Steel
5m
FIXING SCREWS
a) diameter
b) resistance class
c) tightening torque


M12

12.9
80 Nm


M20

12.9
160 Nm

M24
12.9
250 Nm