• 10kg to 2t Load Cell
Mouse over image to zoom

10kg to 2t Load Cell

ISweek online 2h ago

ISweek_com

Send Inquiry Chat Now
  • Price

    Price on request   ≥1piece

  • Model Number

    F3
  • Data Sheet

  • Package

    Original packaging
  • Specs

    F3
  • Quantity

    - +
  • Send Inquiry

Product Description

F3

10kg to 2t Load Cell


Dimensions   [mm]


Technical Data

ACCURACY CLASS: OIML R60
C2
C3
DIVISIONS
2000 3000
NOMINAL LOAD (Emax)
10-25-50-100-200-500kg
1-1.5-2 t
50-100-200-500 kg
1-1.5-2 t
MINIMUM VERIFICATION DIVISION (Vmin)
Emax / 10000
COMBINED ERROR
NON REPEATABILITY
TOLERANCE ON ZERO over 30 min.
CREEP to nominal load:
a) over 30 min.
b) over 20 and 30 min.
≤ ±0.027%
≤ ±0.015%

≤ ±0.021%


≤ ±0.028%
≤ ±0.012%
≤ ±0.027%
≤ ±0.015%

≤ ±0.021%


≤ ±0.028%
≤ ±0.012%
TEMPERATURE EFFECT 10 °C
a) on zero
b) on sensitivity

≤ ±0.023%
≤ ±0.010%

≤ ±0.013%
≤ ±0.009%

NOMINAL SENSITIVITY
SENSIVITY TOLERANCE
2mV/V
≤ ±0.1%
INPUT RESISTANCE
OUTPUT RESISTANCE
INSULATION RESISTANCE
ZERO BALANCE
RECOMENDED SUPPLY VOLTAGE
NOMINAL RANGE VOLTAGE
MAXIMUM SUPPLY VOLTAGE
420 ± 20 Ω
350 ± 2 Ω
> 5 G Ω
≤ ±1%
10 V
1-15 V
18 V
MECHANICAL LIMIT values related to
nominal load:
a) minimum load
b) service load
c) max permissible load
d) breaking load
e) maximum side load
f) max permissible dynamic load
DISPLACEMENT AT NOMINAL LOAD



0%
120%
150%
>300%
200%
75%
~ 0.4 mm

REFERENCE TEMPERATURE
NOMINAL TEMPERATURE RANGE
SERVICE TEMPERATURE
STORAGE TEMPERATURE
+23°C
-10/+40 °C
-20/+70 °C
-20/+80 °C
WEIGHT
~ 1.0 kg
PROTECTION CLASS (EN 60529)
CELL MATERIAL
CABLE LENGTH
IP67
Acciaio Inox / Stainless Steel
5m
FIXING SCREWS
a)  diameter
b)  resistance class
c)  tightening torque


M12

12.9
70 Nm